Generator Set Technische Spezifikation | ||||||||||
Leistung des Generators | Motorleistung | ABMESSUNG L*B*H | ||||||||
Genset-Modell | Primärleistung | Standby-Strom | Fre. | Modell | Leistung | Volllast | Typ öffnen | Gewicht | ||
Kraftstoffkom. | ||||||||||
KW | KVA | KW | KVA | HZ | KW | (L) | (Mm) | (Kg) | ||
GF/GFS-C16KW | 16 | 20 | 26 | 32, 5 | 50 | 4B3.9-G1/G2 | 24 | 5 | 1700*750*1150 | 850 |
GF/GFS-C20KW | 20 | 25 | 26 | 32, 5 | 50 | 4B3.9-G1/G2 | 24 | 6 | 1700*750*1150 | 850 |
GF/GFS-C30KW | 30 | 37, 5 | 33 | 41, 3 | 50 | 4BT3.9-G1/G2 | 36 | 8 | 1820*760*1150 | 900 |
GF/GFS-C34KW | 34 | 42, 5 | 37, 4 | 46, 8 | 50 | 4BT3.9-G1/G2 | 36 | 8 | 1820*760*1150 | 950 |
GF/GFS-C40KW | 40 | 50 | 44 | 55 | 50 | 4BTA3.9-G2 | 50 | 9, 8 | 1950*830*1150 | 1050 |
GF/GFS-C45KW | 45 | 56, 25 | 49, 5 | 61, 9 | 50 | 4BTA3.9-G2 | 50 | 13 | 1950*830*1150 | 1070 |
GF/GFS-C58KW | 58 | 72, 5 | 63, 8 | 79, 8 | 50 | 6BT5.9-G1/G2 | 86-92 | 23 | 2150*880*1350 | 1120 |
GF/GFS-C68KW | 68 | 85 | 74, 8 | 93, 6 | 50 | 6BT5.9-G1/G2 | 86-92 | 23 | 2150*880*1350 | 1120 |
GF/GFS-C80KW | 80 | 100 | 88 | 110 | 50 | 6BT5.9-G1/G2 | 86-92 | 23 | 2150*880*1400 | 1120 |
GF/GFS-C90KW | 91 | 113, 75 | 100, 1 | 125, 1 | 50 | 6BTA5.9-G2 | 110 | 23 | 2350*950*1360 | 1200 |
GF/GFS-C100KW | 100 | 125 | 110 | 137, 5 | 50 | 6BTA5.9-G2 | 110 | 23 | 2350*950*1360 | 1235 |
GF/GFS-C110KW | 110 | 137, 5 | 121 | 151, 3 | 50 | 6BTAA5.9-G2 | 120 | 26 | 2350*950*1360 | 1400 |
GF/GFS-C128KW | 128 | 160 | 140, 8 | 176 | 50 | 6CTA5.9-G2 | 163 | 33, 9 | 2470*950*1430 | 1900 |
GF/GFS-C144KW | 144 | 180 | 158, 4 | 198 | 50 | 6CTA5.9-G2 | 163 | 35, 1 | 2470*950*1430 | 1900 |
GF/GFS-C150KW | 150 | 187, 5 | 165 | 206, 3 | 50 | 6CTA5.9-G2 | 163 | 35, 1 | 2470*950*1430 | 2000 |
GF/GFS-C160KW | 160 | 200 | 176 | 220 | 50 | 6CTAA5.9-G2 | 183 | 38, 7 | 2600*980*1450 | 2300 |
GF/GFS-C180KW | 180 | 225 | 198 | 247, 5 | 50 | 6LTAA8, 9-G2 | 220 | 38, 7 | 2600*1000*1450 | 2400 |
GF/GFS-C200KW | 200 | 250 | 220 | 275 | 50 | 6LTAA8, 9-G2 | 220 | 41, 6 | 2600*1000*1500 | 2500 |
GF/GFS-C20KW | 20 | 25 | 26 | 32, 5 | 60 | 4B3.9-G1/G2 | 27 | 5 | 1700*750*1230 | 850 |
GF/GFS-C22KW | 22 | 27, 5 | 26 | 32, 5 | 60 | 4B3.9-G1/G2 | 27 | 6 | 1700*750*1230 | 850 |
GF/GFS-C30KW | 30 | 37, 5 | 33 | 41, 3 | 60 | 4BT3.9-G1/G2 | 40 | 8 | 1820*760*1240 | 900 |
GF/GFS-C34KW | 34 | 42, 5 | 37, 4 | 46, 8 | 60 | 4BT3.9-G1/G2 | 40 | 8 | 1820*760*1240 | 950 |
GF/GFS-C48KW | 48 | 60 | 52, 8 | 66 | 60 | 4BTA3.9-G2 | 60 | 9, 8 | 1950*830*1270 | 1050 |
GF/GFS-C55KW | 55 | 68, 75 | 60, 5 | 75, 6 | 60 | 4BTA3.9-G2 | 60 | 13 | 1950*830*1270 | 1070 |
GF/GFS-C68KW | 68 | 85 | 74, 8 | 93, 5 | 60 | 6BT5.9-G1/G2 | 92-102 | 23 | 2150*880*1400 | 1120 |
GF/GFS-C80KW | 80 | 100 | 88 | 110 | 60 | 6BT5.9-G1/G2 | 92-102 | 23 | 2150*880*1400 | 1120 |
GF/GFS-C90KW | 90 | 112, 5 | 99 | 123, 8 | 60 | 6BT5.9-G1/G2 | 92-102 | 23 | 2150*880*1400 | 1120 |
GF/GFS-C100KW | 100 | 125 | 110 | 137, 5 | 60 | 6BTA5.9-G2 | 120 | 23 | 2350*950*1360 | 1200 |
GF/GFS-C110KW | 110 | 137, 5 | 121 | 151, 3 | 60 | 6BTA5.9-G2 | 120 | 23 | 2350*950*1360 | 1235 |
GF/GFS-C120KW | 120 | 150 | 132 | 165 | 60 | 6BTAA5.9-G2 | 132 | 26 | 2350*950*1360 | 1400 |
GF/GFS-C144KW | 144 | 180 | 158, 4 | 198 | 60 | 6CTA5.9-G2 | 180 | 33, 9 | 2470*950*1430 | 1900 |
GF/GFS-C150KW | 150 | 187, 5 | 165 | 206, 3 | 60 | 6CTA5.9-G2 | 180 | 35, 1 | 2470*950*1430 | 1900 |
GF/GFS-C160KW | 160 | 200 | 176 | 220 | 60 | 6CTA5.9-G2 | 180 | 35, 1 | 2470*950*1430 | 2000 |
GF/GFS-C180KW | 180 | 225 | 198 | 247, 5 | 60 | 6CTAA5.9-G2 | 201 | 38, 7 | 2600*980*1450 | 2300 |
GF/GFS-C200KW | 200 | 250 | 220 | 275 | 60 | 6LTAA8, 9-G2 | 240 | 38, 7 | 2600*1000*1450 | 2400 |
GF/GFS-C220KW | 220 | 275 | 242 | 302, 5 | 60 | 6LTAA8, 9-G2 | 240 | 38, 7 | 2600*1000*1500 | 2500 |