Gas source | It is advised to use Butane purity ≥99.9% in the standard (customer prepared) |
Burner needle | Internal diameter:¢0.5±0.1mm,external diameter not exceed ¢0.9mm,length exceed 35mm, not allow air to get in |
Test angle | 0°and 45° |
Flame height | 12mm±1mm, adjustable. |
With flame height ruler | |
With standard specimen fixer, height adjustable | |
Test | The specimen move and control by the motor automatically, to keep space between specimen and flame is constant during the test |
Temperature range | 0~999.9ºC,resolution:0.1ºC |
Flame time | 0~99min99s settable,can record the flame holding time(Tb) |
Test control | Use PLC and touchscreen to control the test, stable and easy to use |
Automatic test process | |
Automatic electronic ignition | |
With gas flow and pressure regulate, and over flow protection | |
Fume hood volume | ≥0.75m³,black flat paint wall,illuminance:≤20lux,with air exhaust and lamp |
With remote controller | close the window when testing, and use the remote controller to control the test. Flame temperature calibration device:¢0.5mm K type therrmocouple and copper block |
The temperature of flame | measurement rose from 100 ° C ± 2° C to 700 ° C ± 3 ° C in the time period of 23.5s±1.0s |
Parts | 10mm wooden block*1,silk*1, flame height ruler. |