Description | Specifications | Anr | AG210 |
Gas Detected | |||
Ex | catalytic combustion | √ | - |
toxic gas | electrochemical | - | √ |
infrared | - | √ | |
PID | - | √ | |
Function | |||
measure range | see QUICK-SELECTION-TABLE | √ | √ |
response time* | T90≤30S | √ | - |
T90≤60/180S | - | √ | |
accuracy* | ≤±5%F.S | √ | √ |
repeatability* | ≤2%F.S | √ | √ |
Electric | |||
power supply | 18-28VDC (standard 24VDC) | √ | √ |
power consumption | ≤2.5W | √ | - |
≤1.5W | - | √ | |
signal output | 4-20mA | √ | √ |
RS485 | - | - | |
wiring | three-wire | √ | √ |
four-wire | - | - | |
suitable cable | RVVP3*1.5mm2 | √ | √ |
RVVP4*1.0mm2 | - | - | |
relay output | 1 passive relay (250VAC/5A 30VDC/5A) | √ | √ |
Display&operation | |||
display | OLED display | √ | √ |
indicator light | power,fault,alarm-1,alarm-2 | √ | √ |
operation method | key operation | √ | √ |
Environment | |||
ingress protection | IP65 | √ | √ |
operating temperature | -40ºC~70ºC | √ | - |
-20ºC~60ºC | - | √ | |
operating humidity | 10~95%RH non-condensing | √ | √ |
operating pressure | 80-120kPa | √ | √ |
Structure | |||
body material | ADC12 aluminum alloy +316L stainless steel | √ | √ |
close nipple | NPT1/2 | √ | √ |
weight | about 1.5kg | √ | √ |
dimensions | 165*140*78mm(H*W*D) | √ | √ |
Certificates | |||
CPA | 2013C293-32 | √ | √ |
EX | ExIICT6 Gb | √ | √ |
CCCF | 073184850124ROM | √ | - |
SIL | SIL2 | √ | √ |
ATEX | ExdIICT6 Gb | √ | √ |
Note:* refers to there's some difference vary from different gas, please contact the manufacturer for details. |