Medical Dialysis center  HDF  therapy Hemodialysis MET6008S kidney therapy
 
Intelligent operation system; Easy operation with visual and audio alarms; Multi-purpose
service/maintenance interface; Profiling: sodium concentration and UF curve;

Main performance of this device:
1. On-line HDF
2. Self-checking function;
3. Carbonate dialysis;
4. Double needle dialysis;
5. Liquid level detector;
6. Bubble detector;
7. Blood leakage detector;
8. Temperature and electric conductivity monitoring;
9. Arterial pressure, venous pressure and transmembrane pressure monitoring;
10. Rolling blood pump;
11. Heparin pump;
12. Dehydration amount controlled by capacity;
13. Automatic disinfection cleaning program;
14. Stand-by power of blood pump in case of power failure;
15. Information display function of display screen.
me periods through different "one-button" operation, and automatically complete the whole process of dialysis treatment.
Technical Parameter
Size &Weight:
Size: 380mmx400x1380mm (L*W*H);
Net Weight approx.: 88KG;
Gross Weight approx.: around 100KG;
Package Size approx.: 650×690×1581mm (L x W x H)
Power supply:
AC220V, 50Hz/60Hz, 10A
Input power: 1500W
Back-up battery: 30 minutes
Working Condition:
Water input pressure: 0.1Mpa~0.6Mpa, 15P.S.I~60P.S.I
Water input temperature: 5ºC~30ºC
Working environment temperature: 10ºC~30ºC at relative humidity <=70%
UF rate:
Flow range: 0ml/h~4000ml/h
Resolution ratio: 1ml
Precision: ±30ml/h
Blood pump & substitution pump:
Blood pump flow range: 10ml/min~600ml/min (diameter: 8mm or 6mm)
Substitution pump flow range: 10ml/min~300ml/min (diameter 8mm or 6mm)
Resolution ratio: 0.1ml
Precision: ±10ml or 10% of reading
Heparin pump:
Syringe size: 20, 30, 50ml
Flow range: 0ml/h~10ml/h
Resolution ratio: 0.1ml
Precision: ±5%
Monitoring system &Alarm setup:
Venous pressure: -180mmHg ~ +600mmHg, ±10mmHg
Arterial pressure: -380mmHg ~ +400mmHg, ±10mmHg
TMP: -180mmHg ~ +600mmHg, ±20mmHg
Dialysate temperature: preset range 34.0ºC~39.0ºC
Dialysate flow: Less than 800 ml/min (Adjustable)
Substitution flow range: 0-28 L/H (on line HDF)
 
Blood leak detection: Photo chromic alarm when erythrocyte specific volume is 0.32±0.02 or
blood leak volume is equal or more than 1ml per liter of dialysate.
Bubble detection: Ultrasonic, Alarm when a single air bubble volume is more than 200μl at
200ml/min blood flow
Conductivity: Acoustic-optic








 