Economical Double Cylinder 660 MW Air-Cooled Steam Turbine

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ 200000

Description
Product Details
     Induction furnace is used for smelting or insulating ferrous metals, non-ferrous metals, sponge iron, such as scrap iron, scrap steel, copper, aluminum and so on. Complete working equipment such as continuous casting machine, rolling mill, mainly used for the production of billet, steel bar, angle steel, H-beam, I-beam, etc. Using KGPS, IGBT, single or double power supply technology, PLC (Siemens) can be realized throughout the monitoring.
 
       Main supply list: 2 sets of electric furnace body, 2 sets of hydraulic or mechanical tilting electric furnace mechanism, 1 set of control platform, 1 set of intermediate frequency control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), low voltage control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), 1 set of capacitor cabinet, 4 or 8 water-cooled cables; 1 water temperature alarm, 1 leakage alarm; 1 crucible mold, 1 liquid One batch of pressure steel pipe, one set of copper row, three water tanks. Transformer, cooling tower, furnace builder, furnace lining ejector, furnace cover.

KGSP Induction Electric Furnace


GW-8-4000-0.5J KGSP Induction Electric Furnace



GW-1-750-1JJ Medium frequency coreless electric furnace


GW-50-22000-0.2J No induction melting furnace


GW-0.25-160-1JJ melting electric furnace

GW-1.5-1000-1J Medium frequency induction furnace




 
NO.Electric 
Furnace 
Type
Input 
power
(KW)
input 
voltage
(V)
Input 
current
(A)
Rated 
power
(KW)
DC 
current
(A)
DC 
voltage
(V)
Melting 
rate
(T/H)
working 
frequency
(HZ)
working 
voltage
(V)
cooling water
 pressure(MPA)
Rated 
capacity
(T)
Power 
consumption
(KWH/T)
Power 
Supply
Furnace 
body
1GW-0.25-160/1JJ180380
(6 Pulse)
2561603205000.2410007500.1~0.150.25~0.30.25790
2GW-0.5-250/1JJ280380
(6 Pulse)
4002505005000.4100015000.1~0.150.25~0.30.5770
3GW-0.5-250/1J280380
(6 Pulse)
4002505005000.4100015000.1~0.150.25~0.30.5770
4GW-0.75-400/1JJ400380
(6 Pulse)
6504008005000.6100015000.1~0.150.25~0.30.75770
5GW-0.75-400/1J400380
(6 Pulse)
6504008005000.6100015000.1~0.150.25~0.30.75770
6GW-1-500/1JJ550380
(6 Pulse)
80050010005000.8100015000.1~0.150.25~0.31750
7GW-1-750/1JJ800380/690
(6 Pulse)
1200/
700
7501500/
850
500/
880
0.91000/
500
1500/
2600
0.1~0.150.25~0.31720/660
8GW-1-750/1J800380/690
(6 Pulse)
1200/
700
7501500/
850
500/
880
0.91000/
500
1500/
2600
0.1~0.150.25~0.31720/660
9GW-1.5-1000/0.5JJ1100690
(6 Pulse)
912100011408801.250026000.1~0.150.25~0.31.5700
10GW-1.5-1000/0.5J1100690
(6 Pulse)
912100011408801.250026000.1~0.150.25~0.31.5700
11GW-2-1500/0.5JJ1650690
(6 Pulse)
1360150017008801.750026000.1~0.150.25~0.32675
12GW-2-1500/0.5J1650690
(6 Pulse)
1360150017008801.750026000.1~0.150.25~0.32675
13GW-2-2000/0.5JJ2200690
(6 Pulse)
1400200022758801.950026000.1~0.150.25~0.32650
14GW-3-2500/0.5JJ2750690/950
(6 Pulse)
2275/
1700
25002840/
2080
880/
1250
2.565002600/32000.1~0.150.25~0.33610/560
15GW-3-2500/0.5J2750690/950
(6 Pulse)
2275/
1700
25002840/
2080
880/
1250
2.565002600/32000.1~0.150.25~0.33610/560
16GW-4-3000/0.5J3300690/950
(6 Pulse)
2730/
2040
30003410/
2500
880/
1250
3.25002600/32000.1~0.150.25~0.34610/560
17GW-5-4000/0.5J4400950
(6 Pulse)
2300400033301250550034000.1~0.150.25~0.35600/550
18GW-6-4000/0.5J4400950
(12 Pulse)
2300400033301250550034000.1~0.150.25~0.36600/550
19GW-8-5000/0.5J5000950
(12 Pulse)
34005000420012507~850034000.1~0.150.25~0.38600/550
20GW-10-6000/0.5J6300950
(12 Pulse)
37506000460012508.5~950034000.1~0.150.25~0.310600/550
21GW-12-8000/0.25J8000950
(12 Pulse)
49008000600012509~10.525034000.1~0.150.25~0.312600-550
22GW-15-8000/0.25J8000950
(12 Pulse)
49008000600012509~10.525034000.1~0.150.25~0.315600-550
23GW-15-10000/0.25J10000950
(24 Pulse)
6500100008000125013~1525034000.1~0.150.25~0.315600-550
24GW-18-12000/0.25J12000950
(24 Pulse)
81601200010000120015~1725034000.1~0.150.25~0.318600-550
25GW-20-12000/0.25J12000950
(24 Pulse)
81601200010000120017~1925034000.1~0.150.25~0.320600-550
26GW-25-14000/0.25J14000950
(24 Pulse)
94601400011600120019~21150~20034000.1~0.150.25~0.325600-550
27GW-30-16000/0.2J16000950
(24 Pulse)
108501600013300120021~23150~20034000.1~0.150.25~0.330600-550
28GW-40-20000/0.2J20000950
(24 Pulse)
135452000016600120025~27150~20034000.1~0.150.25~0.340600-550
29GW-50-22000/0.2J22000950
(24 Pulse)
149322200018300120025~28150~20034000.1~0.150.25~0.350600-550

Note:
(1) GW - means medium frequency induction furnace, - 1 - means induction furnace capacity of 1 ton, - 500 - means furnace rated power of 500 KW, / 1 - means furnace operating frequency of 1000 Hz, / 0.5 - means melting furnace frequency of 500 Hz, - J - means hydraulic tilting furnace (furnace shell is steel shell), - JJ - means mechanical tilting furnace. (the shell of the furnace is aluminum alloy).

(2) The above quoted price is for routine configuration. Other configurations can be added, such as leak alarm, water temperature alarm, furnace switch, cover mechanism, lining ejector and transformer, cooling device (open and close cooling tower, closed cooling tower, plate heat exchanger)

3) If necessary, send technicians to carry out the commissioning: the domestic section is free; the overseas section travel expenses, accommodation and food are borne by the user and each person is subsidized 150 US dollars per day.

4) I quote EX-W at a price including simple packing, including shipping charges to Shanghai port area and all inland charges in China.

V) The above electric furnace voltage levels are 380V, 690V and 950/1000V, and the frequency is 50HZ. If the user equipment requirements are different from the above voltage levels and frequencies, each item needs to be increased by 15000USD.
 
  
  
  

A complete set of steam turbine island comprises of following equipments and sub-systems: 

1.Turbine-generator set  -
--power is generated through the action of generator driven by the turbine connected to it.
2.Water-condensation system
--
steam is condensed to water to be circulated to boiler and heated again.
3.Vacuum system 
    A.sub-system of main steam (
where steam circulates to propel the blades of turbine)
    B.water cycle system (
where water circulates from condenser to be heated again)
    C.DCS system (
monitors the operation of turbine and adjusts output rate)
    D. deaerating &water supplying system (
where oxygen is removed to ensure good operation environment and water is supplied)
4. Cooling Air system 
(for air-cooled unit only)
5. Generator system ( electricity is generated in this system)

Our protocol of delivering power plant construction project is as follow:
 
1.The Argumentation of Project
2. Engineering Design
    a. Turbo-Gen Set and its auxiliary systems
    b.Layout of Condensed Water System
    c.Layout of Heat System
    d.Civil Construction and Structure of Turbo-Gen Set
3.Equipment Purchase
    a.Turbo Generator Set and its auxiliary systems
    b.Condensed Water System
    c.Vacuum System
    d.Lower Temperature Heating System
4. Civil Construction
    a.Foundation and the upper structure of the Turbo Generator House
    b.Foundation of Turbo-Gen Set and its auxiliary systems
    c.Foundation of other structures
5. Operation & Maintenance
    a.Operation of power plant (technical counseling)
    b.Regular maintenance and inspection
    c.Technical Training Program for power plant personnel
    d.General Overhaul
6. Installation & Testing
    a.Installation & testing for all systems & equipment provided
    b.Installation, testing & trail run of all systems of a power plant (Optional)
    c.Installation, testing & trail run of entire power plant (Optional)
7. Supply of Spare Parts

Reference List 
No.ItemProject detail
01CommissionerLafargeHolcimCentury Paper MillPolatSPGCL
02LocationGombe State, NigeriaLahore, PakistanTurkeyIndia
03Scope of serviceEPC projectEngineering, Purchase, Supervision of constructionEPC projectEPC project
04Applicationservice power plant
of a cement factory
service power station of a paper millindependent power plantindependent power plant
05Modelair-cooled condensing 
turbine island
condensing/extracting turbinecondensing turbinereheat turbine
06BrandSimonsHTPHTPHTC
07Standard of engineeringDIN.GBGBGB
08Layoutsingle-story layout with horizontal steam dischargedownward steam dischargedownward steam dischargedownward steam discharge
09Technical parameterspresure of steam inlet:8.5MP
tem. of steam inlet: 435C.
rated power:16.5MW
back pressure:15KPa
presure of steam inlet:4.9MP
tem. of steam inlet: 475C.
rated power:18MW
pressure of extraction:1.1MP
flow of extracted steam:54.6Mpa
back pressure:15KPa
presure of steam inlet:8.83MP
tem. of steam inlet: 435C.
rated power:51MW
back pressure:4.9KPa
presure of steam inlet:16.7MP
tem. of steam inlet: 538C.
rated power:300MW
pressure of extraction:1.1MP
back pressure:10KPa
10Performance (under standard condition)heat rate:2467kcal/kw
steam rate:4.16kg/kw
heat rate:2206.5kcal/kwheat rate:2215.3kcal/kw
steam rate:4.16kg/kw
steam rate:3.64kg/kw



Product Tag:
Related categories:
Scroll to Top