100A 200A Micro-Ohmmeter Circuit Breaker Contact Resistance Test Kit

Min.Order: 1
Product origin: Wuhan, Hubei, China
Infringement complaint: complaintComplaint
US$ -1

Description
1.Overview
Micro-Ohmmeter (Loop resistance tester/Low Resistance tester) is the special test equipment for measuring the contact resistance and loop resistance of some devices such as switch, circuit interrupter, and transformer and so on. It adopts the typical four-wire method of measurement which helps get the DC resistance through the following steps: outputting a DC current, applying the current to the tested body by linking its two terminals, and measuring the voltage drop when the current goes through the tested body, then dividing the current by the voltage. In addition, it mainly consists of constant current source, preamplifier, A/D converter, indicating device and so on. It is designed according to IEC62271.

2. Features and functions
1)Design with hardware and software: Endowing the instrument with some features such as high measuring speed, numerical stability, and good repeatability and so on by using electronic circuit of high precision and SCM of high performance.

2) Real-time monitor will display site resistance and current.

3) If the duration of current is over 1 minute, it completely accords with the verification regulation of JJG 1052-2009 loop resistance.
4) A 100A/200A/300A/400A/500A/600A/700A switch constant-current supply of high precision, for testing the current, can test quickly and accurately without manual adjustment.

5) It has the functions of printing, storing, real-time viewing data and so on.

6) It is with a large screen to display characters, menus to operate, and friendly interfaces to understand and process easily.

7) Miniature printer is thermal printer with fast speed, which can be installed printing paper directly.

8) It can also measure when exchanging wirings between positive and negative poles of voltage, and between positive and negative poles of current.

9) Manage the data of equipment through serial port RS232 instead of paper.

3. Technical parameter

Model HLY-100  (50A/100A)
1) Measurement range:   
       50A   0 ~ 40mΩ(40Ω): last 300S

     100A   0 ~ 20mΩ(20Ω): last 120S
2) Measurement precision: Better than 0.5%
3) Resolution: 0.01μ Ω
4) Operating mode: Continuous measurement
5) Display mode: LCD
6) Computer interface: RS232
7) Print way: Thermal printing
8) Environment condition:
Temperature: -10ºC-50ºC
Relative humidity: < 90%(25ºC)
Elevation: ≤ 1500m
Power supply frequency: 50Hz± 1Hz
9) Power: ≤ 3100W
10) Boundary dimension: Length 460 mm*width 400mm*height 380mm
11) Weight: 16.5 Kg.


Model HLY-200  (50A/100A/200A)
1) Measurement range:
        50A  0 ~ 40mΩ  last 300S
      100A  0 ~ 20mΩ  last 120S
     200A  0 ~ 10mΩ  last 60S
2) Measurement precision: better than 0.5%
3) Resolution: 0.01μΩ
4) Operating mode: continuous measurement
5) Display mode: LCD
6) Computer interface: RS232
7) Print way: thermal printing  
8) Environment condition:
          Temperature: -10ºC ~ 50ºC
          Relative humidity: < 90%(25ºC)
          Elevation:1500m
          Power supply frequency: 50HZ±1HZ
9) Power: ≤1000W
10) Size: length 460 mm*width 400mm*height 380mm
11) Weight: 18 Kg (with cables).





Model HLY-400  (100A/200A/300A/400A)
1) Measurement range:    100A  0 ~ 40mΩ  last 120S
                                         200A  0 ~ 20mΩ  last 120S
                                          300A  0 ~ 13mΩ  last 60S
                                          400A  0 ~ 10mΩ  last 30S
2) Measurement precision: better than 0.5%±0.2uΩ
3) Resolution: 0.01μΩ
4) Operating mode: continuous measurement
5) Display mode: LCD
6) Computer interface: RS232
7) Print way: thermal printing  
8) Environment condition:
          Temperature: -10ºC ~ 50ºC
          Relative humidity: < 90%(25ºC)
          Elevation:1500m
          Power supply frequency: 50HZ±1HZ
9) Power: ≤2100W
10) Size: length 460 mm*width 400mm*height 380mm
11) Weight: 22 Kg
 


Model HLY-600  (100A/200A/300A/400A/500A/600A)
1) Measurement range:

                  100A  0 ~ 20mΩ  last 300S
                 200A  0 ~ 10mΩ  Last 120S
                 400A  0 ~ 5mΩ   Last 80S
                 600A  0 ~ 3mΩ   Last 60S
2) Measurement precision: better than 0.5%
3) Resolution: 0.01μΩ
4) Operating mode: continuous measurement
5) Display mode: LCD
6) Computer interface: RS232
7) Print way: thermal printing  
8) Environment condition:
          Temperature: -10ºC ~ 50ºC
          Relative humidity: < 90%(25ºC)
          Elevation:1500m
          Power supply frequency: 50HZ±1HZ
9) Power: ≤3100W
10) Size: length 460 mm*width 400mm*height 380mm
11) Weight: 26 Kgs




 
 
  Item 
                                                      HLY
  100A     200A   400A 600A
Output Current50A/100A 
50/100/200A
 
100/200/300/400A100/200/400/600A
Test Range50A  0~40mΩ
100A  0~20mΩ

 
50A  0~40mΩ 
100A  0~20mΩ 
200A  0~10mΩ
100A  0~40mΩ 
200A  0~20mΩ
300A  0~13mΩ 
400A  0~10mΩ 
100A:0~20mΩ                          
200A  0~10mΩ 
400A  0~5
600A  0~3
Resolution 0.01μΩ  0.01μΩ 0.01μΩ 0.01μΩ
Accuracy± 0.5%± 0.5%± 0.5%± 0.5%
Operation mode continous continouscontinouscontinous
Interface RS232RS232RS232RS232
Power≤1000W≤1000W2100W3100W
Temperature-10ºC~45ºC-10ºC~45ºC-10ºC~45ºC-10ºC~45ºC


4.Accessory
Sr noDescription
 
Qty
 1Power supply cable1 unit
 2Test cables1 set
 3Soft driver1 unit
 4Printer paper1 unit
 5Factory's calibration report1 unit
 6Operating manual1 unit
 7Pack/Aluminium alloy box for
accessories
1 unit






Product Tag:
Related categories:
Scroll to Top