Vlf AC Hipot High Voltage Insulation Withstand Voltage Tester 80kv

Min.Order: 1
Product origin: Wuhan, Hubei, China
Infringement complaint: complaintComplaint
US$ -1

Description
VLF (Very Low Frequency) Hipot Testers are suitable for testing power cables, transformers, switchgear, rotating machinery and other electrical apparatus.

The VLF sereis only supply AC withstand voltage testing.
For buyer's option:
1.Tan delta (tgδ test for option), capacitance (μF) and IR (Ω) Test without external device.
2."IEE 400.2" Analysis of Tan delta test result.
3.Partial discharge testing without external device .
4.DC withstandi voltage test,DC leakage current measuremen.

-Micro-controller
-Advanced digital frequency technology
-Built-in printer
-Discharge free
-Portable
-60mins Continous working
-CE mark
-Patent
-5th generation


                                    AC withstand voltage testing

                                DC withstand voltage testing

VLF Advantage
1.AC Withstand voltage testing, Voltage & current curve display.
2.Tan delta (tgδ test for option), capacitance (μF) and IR (Ω) Test without external device.
3.Partial discharge testing without external device .
4.DC withstandi voltage test,DC leakage current measurement (for buyer's option).
5."IEE 400.2" Analysis of Tan delta test result.
6.Safe Optical isolation technology.
7. Easiest to use Fully automatic microcontroller.
8. H/L voltage closed loop negative feedback control circuit, output no capacity rise effect.
9. Built-in printer.
10. Built-in protective resistors.                              
11. Colour Touch LCD (154*86mm)operation, True sine wave output.
12. Real-time display of actual output waveform.       
13. Ergonomic, menu guided, large colour touch screen
14. Storage of test results for later retrieval and print.                       
15. Over voltage and current protected.
16.Auto variable frequency 0.1Hz, 0.05Hz, 0.02 Hz, 0.01 Hz.
17. 60 mins continuous working;
18. Data of current, voltage and waveform directly sampled at HV side.
19. Rugged and reliable design less prone to failure from transients.
20. Invatation Patent                                                   
21. Portable: Control unit + Booster (Tank)
22. CE mark.
23. RS232 for option.

Specification
1.Power: 220V ± 10% AC (110V can be customized), 50/60Hz, single phase;
2.Output-Voltage (Peak): 1 to rated value (KV), details see the below table;
3.Output frequency: 0.1Hz, 0.05Hz, 0.02 Hz, 0.01 Hz (auto variable frequency);
4.Load: 0.5μF (approx 6,000 ft of cable)  @ 0.1 Hz 
       1.0μF (approx 12,000 ft of cable) @ 0.05 Hz 
       2.5μF (approx 30,000 ft of cable) @ 0.02 Hz 
       5.0μF (approx 60,000 ft of cable) @ 0.01 Hz 
5. Stability of frequency: Fluctuation < 0.5%;
6. Measurement accuracy: ±3%;
7. Positive and negative voltage peak error: ≤3%;                             
8. Voltage waveform distortion: ≤5%;                                 
9. Construction: 1 Control unit + 1 Booster (60KV set);  1 Control unit + 2 Boosters(60KV set).
10. Ambient conditions of use: temperature Indoor and outdoor : -10ºC ~ + 50ºC.         
11. Humidity:≤85% 
12. Technical indexes of VLF tgδ test (for option):
  1) tgδ test voltage range: 1 to 40KV (Only one booster can be used for tan delta test if 2 boosters set)
  2) Measurement voltage accuracy: 3%
  3) Dielectric loss test frequency: 0.1Hz
  4) Measurement range: 0.01×10-3- 655.35×10-3
  5) Dielectric loss accuracy: 1x10-4
  6) Dielectric loss resolution: 1x10-5
  7) Capacitance measurement range: 0.001μF-10μF
  8) Celectric capacity resolution: 0.001μF                    
  9) Current measurement range: 0-59mA                         
  10) Current resolution: 0.1mA
  11) Insulation resistance: 0.01GΩ-65.53GΩ
  12) Insulation resistance resolution: 10

13.Main technical indexes of VLF PD test :
  1) Partial discharge measurement range: 0.01pc-200pc
  2) Partial discharge detection sensitivity: 0.01pc
  3) Capacitance range: 0.001μF-10μF
  4) Sampling bits: 12 bits
  5) Sampling speed: 12M/S                                           
  6) Test voltage:  0 to rated value (KV)

14.DC leakage current measurement (for option):
  1) Output rated voltage: same as rated AC voltage output
  2) Voltage accuracy: 3%
  3) Leakage current range: 0-2000μA
  4) DC Current resolution: 1μA
  5) DC current accuracy: 3%
  6) It is necessary to parallel the capacitor we supplied if testing DC leakage current.
 

Model no
Output
Voltage/
Current
(Peak)
Load CapacityControl UnitBooster(Tank)Power 
Capacitance/
Freuency
Net Dim.
(cm)
Net Wt
 (kg)
Net Dim.
(cm)
Net Wt
(kg)
VLF-30 30KV/20mA0.1Hz-0.01Hz
Auto Variable
Capacity:≤10µF
40×31×20  629x15×35251000W
VLF-40 40KV/20mA0.1Hz-0.01Hz
Auto Variable
Capacity:≤10µF
40×31×20  629x15×35251200W
VLF-50 50KV/30mA0.1Hz-0.01Hz
Auto Variable
Capacity:≤10µF
40×31×20  645×19×36451500W
VLF-60 60KV/59mA0.1Hz-0.01Hz
Auto Variable
Capacity:5µF at 60KV;
40×31×20  645×19×36
 
452000W
VLF-70 70KV/59mA0.1Hz-0.01Hz
Auto Variable
Capacity:5µF at 70KV;
Capacity:10µF for single booster (30/40KV)

40×31×20
 
  629x15×35    252500W
36x19×45    45
VLF-80 80KV/59mA0.1Hz-0.01Hz
Auto Variable
Capacity:5µF at 80KV;
Capacity:10µF for single
booster (30/50KV)
40×31×20
 
  629x15×35    253000W
36x19×45    45
VLF-90  90KV/59mA0.1Hz-0.01Hz
Auto Variable
Capacity:5µF at 90KV;
Capacity:10µF for single
booster (40/50KV)
40×31×20  629x15×35    253500W
36x19×45    45

Field connection diagram (Test object: cable)







True LCD screenshoot test results




Package for transport :
 
1) 30KV/40KV test set:
Sr no Name of Commodity  Qty N.W G.WTransport size
(LxWxH)

1
 
Controller 1 unit5 kg
52 kg

450x380x800mm
Capacitor 0.04µF1 unit5 kg
Booster I (30/40KV)1 unit25 kg
Aluminum alloy box1 unit5kg
                    Total:1 set40 kg52 kg0.14 m3
                                                       Packed in 1 wooden case.
 
2) 50KV/60KV test set:
Sr no Name of Commodity  Qty N.W G.WTransport size
(LxWxH)

1
 
Controller 1 unit5 kg
80 kg

470x430x950mm
Capacitor 0.04µF1 unit5 kg
Booster I (50/60KV)1 unit45 kg
Aluminum alloy box1 unit5kg
                    Total:1 set60 kg80 kg0.19 m3
                                                       Packed in 1 wooden case.


 
2) 70KV/80KV test set:
Sr no Name of Commodity  Qty N.W G.WTransport size
(LxWxH)

1
 
Controller 1 unit5 kg
52 kg

450x380x800mm
Capacitor 0.04µF1 unit5 kg
Booster I (30/40KV)1 unit25 kg
Aluminum alloy box1 unit5kg
2Booster II (40/50KV)1 unit45 kg69 kg470x430x720mm
Aluminum alloy box  1 unit6 kg
 
                    Total:1 set91 kg121 kg0.29 m3
                                                      Packed in 2 wooden cases.


           
Accessories
Sr no.     DescriptionQuantityRemarks
  1Control unit1unit 
  2Booster I (Tank I)1unit1 Booster if ≤60KV set;
2 boosters for ≥70KV set.
Booster II (Tank II)1unit
  3Capacitor (0.04µF)1unitUsed as Capacity supplement, or test object for demo
  4Discharge rod1unit 
  5HV Test/Connection cables1set 
  6Earth cable1unit 
  7Power supply cable1unit 
  8Fuse2units 
  9Printer paper1unit 
 10Operating manual 1unit 
 11Aluminium alloy box1unit1 aluminium alloy box ≤60KV set;
2 aluminium alloy boxes ≥70KV set.
1unit
 12Calibration report1unit 






Product Tag:
Related categories:
Scroll to Top