Description
XR30CX-5N0C1 Dixell Digital Temperature Thermostat Control for FRIDGES FREEZERS dixell temperature controller
1.Innovative digital controllers dedicated to heat and M.T.-L.T. refrigeration
2.Easy and intuitive programming mode
3.Display with icons and integrated measurement units
4,On/off key
5.Plastic front frame with "cut out" "WING" compatible
6.Up to 2 light switches
7.Energy saving cycles through digital input
8.Fast freezing with dedicated set point
9.Regulation stop through auxiliary probe
10.Regulation restart with door open alarm
11.Temperature or HACCP Max and Min function
12.Configurable digital input also as probe
Main technical parameters of Dixell electronic controller
FEATURES | XR20CX | XR30CX | XR40CX | XR60CX |
Display:n°digits Power supply | ±3d.p. 12,24Vac/dc 24,110,230Vac 9÷40Vac* | ±3d.p. 12,24Vac/dc 24,110,230Vac 9÷40Vac* | ±3d.p. 12,24Vac/dc 24,110,230Vac 9÷40Vac* | ±3d.p. 12,24Vac/dc 24,110,230Vac 9÷40Vac* | ±3d.p. 12,24Vac/dc |
Probe inputs | | | | | |
Thermostat Thermostat2 Defrost Defrost2 Condenser | NTC/PTC NTC/PTC On HOT KEY | NTC/PTC NTC/PTC On HOT KEY | NTC/PTC NTC/PTC NTC/PTC On HOT KEY | NTC/PTC NTC/PTC NTC/PTC On HOT KEY | NTC/PTC NTC/PTC NTC/PTC On HOT KEY |
Digital inputs | | | | | |
Alarm,start defrost,AUX Door switch,pressure switch,probe Alarm,start defrost,AUX Door switch, pressure switch | config | config | config | config | config |
Relay outputs | | | | | |
Computer Computer2 Thermostst2 Defrost Defrost2 Fans Light or alarm Anti-sweat | 8A,20A opt | 8A,20A opt 8A | 8A,20A opt 8A | 8A,16A opt 8A 8A | 20A 8A 8A |
Other | | | | | |
Hot Key/Prog Tool Kit output Remote display output Serial output Buzzer Real time clock | Pres X-REP opt TTL opt | Pres X-REP opt TTL opt | Pres X-REP opt TTL opt | Pres X-REP opt TTL opt | Pres X-REP opt TTL opt |
XR20CX : Digital Dixell controller for N.T. with "off cycle" defrost
XR30CX: Digital Dixell controller for N.T. with "off cycle" defrost and additional configurable reply
XR40CX: Digital Dixell controller for M.T. and L.T. with electrical or hot gas defrost
XR60CX: Digital Dixell controller for M.T. and L.T. ventilated application with dual humidity function
13.Virtual probe management
14.Conderser temperature management to prevent critical plant situations
15.Hot key connector for a quick and easy programming
16.Serial line connection to monitoring systems
17.Connection for X-REP remote display(alternative to TTL output)
18.3VA max power absoraption
19.Display with red LED(10,5mm high) and icons