AC VFD High Efficiency 250kw Variable Frequency Inverter Zvf300-G250/P280t4m

Min.Order: 1
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 5069 ~ 5079

Description
ZVF300 Series frequency Inverter has the good effect energy conservation , fine speed adjustment performance , stable operation , stable operation , electrical machinery soft start, protect function and self diagnostics fault and other advantages.
 

 ZVF300 Series frequency Inverter is suitable for all kinds of devices such as metallurgy, plastic,   textile machinery ,   paper manufacturing machinery, food machinery, petrification equipment, drugs manufacture, steel and iron equipment , printing mechanism ,  packing machinery , blower fan, water pump,hoisting equipment , building materials  and so on for driving  and speeding control of AC asynchronous motor .

PACKING SIZE
 
Inverter Model Power (kW ) Gross Weight (kg)Packing Size  (mm )Gross Weight (kg)Net Weight (kg)
ZVF300-G250/P280T4M250/280kW 380V230.0kg1760*775*510mm/1PCS248kg230kg



DIMENSION:(UNIT:MM)
Inverter ModelPower
(KW)
G/P
Current
 (A)
  Dimension (mm)
HH1WW1Dd
ZVF300-G250/P280T4M250/280470/5201600 660 415 




SPECIFICATION AMD TECHNICAL INDICATION
ItemItem Description
Control FunctionAutomatic energy-saving operationAuto optimize V/F curve according to the load changes to realize the energy saving operation.
Auto voltage regulation(AVR)When the network voltage changes, it can regulate PWM output automatically to maintain constant voltage.
Built-in PIDThis can form a convenient closed-loop control system (CLCS)and is applicable to pressure control, flow control and other process control  .
Operation FunctionOperating commandOperation panel control ,external terminal control and COM control
Frequency settingKeypad potentiometer setting , operation panel  setting,. external terminal UP/DOWN setting, analog voltage signal or external potentiometer setting , analog current signal setting .terminal combination setting ,485 COM setting and so on.
Input SignalForward/Reverse signal\multi-speed signal \fault signal \
reset signal etc.
Output signalProgrammable relay\open collector output \Fault  signal output.
Multi-function analog and digital output terminalThis can realize the output of frequency current and other physical quantity by output 0-10V or 0-20mA DC signal and 0-10KHz digital signal output.
Braking functionDynamic brakingWith an external braking resistor, the maximum braking torque may reach 100%.
DC BrakingThis can be selected when the motor starts or stops with the action frequency of 0-20Hz,action current level of 0-100% and actuation time of 0-30sec., which can be set in sequence.
Other FunctionSkip frequency\Jog function\Counter \Rotation speed tracking\Momentary power loss restart \Frequency upper/lower limiting\Acceleration/ Deceleration mode can be adjusted \Frequency meter and Voltmeter output \Multi-speed/ program running \Two wire mode/ three wire mode control \Wobble frequency control\Multi-function input terminal selection \Fault auto reset\RS485 serial communication .
Protection FunctionInput phase loss protection\Over current protection \Overload protection\Over voltage protection \Under voltage protection\Over heat protection ect.

CHZIRI CERTIFICATE