HVHIPOT Safety Equipment Testing - Electrical Safety Testing and Test Equipment

Min.Order: 1
Product origin: Wuhan, Hubei, China
Infringement complaint: complaintComplaint
US$ -1

Description





General introduction


GDJS-6Insulation Gloves (Boots) Test Set is special equipment for batch test of insulated gloves (boots),which simplify test procedure, improve test speed and reduce test strength. It guarantees personnel security and identifies parameters of leakage current, insulation aging and power frequency voltage reliably.6pcs insulated gloves(boots) can be tested at the same time.
 

Features

    Manual control unit

  • Digital and real time display HV voltage, LV current, 6-way leak current and time.
  • With leak current meter and over-current protection meter.
  • With movable control unit, easy wiring and testing.
  • Manual control, safety and reliability.
  • With zero, power, operation, timing indicators.
  • With over-current protection, zero-start protection, sound and light alarm, power protected switch.
  • New type timer, broader timing range.(1s-99h)

Other features

  • HV source is oil immersed type testing transformer.(dry type and SF6 gas type for option.)
  • It is suitable for testing insulation gloves(boots), 6-110kV insulation rod and 6-110kV electroscope.
  • To make test for insulation gloves and boots, the HV electrode is chain type, which the height can be
  • adjusted. The material is stainless steel with CU/EpNi5bc painted, which make surface
  • discharge<10pc. 6pcs insulation barrels are also supplied.
  • The electrode of insulation boots is red cooper voltage-sharing type, the HV inside the bottom of
  • boots are equal distribution. 4mm steel balls supplied, not using traditional way that injecting water.
  • With insulation rod stand to make withstand voltage and leak test for insulation rod. (Optional)
  • With electroscope testing device to make start voltage, in-phase, out-phase interference test for
  • electroscope. (Optional)
  • With electrode for withstand voltage and leak test of insulation mat and blanket.(Optional)
  • Control unit and HV unit are separate, to ensure safety.
  • If there is breakdown or over limits, the HV output will be cut off automatically and alarm.


Technical Specifications

  • Rated capacity5kVA
    Input voltageAC220V±10%, 50Hz±1
    Output voltage0-50kV
    Voltage accuracy 2.0%(F.S)
    LV current0-25A
    Leak current0-20.0mA
    Resolution of leak current 0.1mA
    Current accuracy1.5%
    Timing range0-99h
    Environmental temperature-20-50degree
    •  
Product Tag: