Item | Model | MPPT48Z-80M | MPPT48Z-100MI |
Output | Rated Charge Voltage | DC12V/24V/36V/48V Automatic recognition |
Output VDC Precision | ≤±1.5% |
Rated Charge Current | 80A | 100A |
Load Rated output Current | 80A | 100A |
Current-limiting Protection | 85A | 105A |
Over Charge Protection | DC 9V~15V for 12VDC , DC18V~28V for 24VDC, DC32V~40V for 36VDC,DC42V~60V for 48VDC |
Selectable battery | Sealed lead acid, vented Gel, NiCd.Other types of the batteries also can be defined |
Temperature Compensation | 14.2V-(The highest temperature-25ºC)*0.3 |
Input | MPPT Range | 16V~DC150V For 12VDC ,30V~DC150V For 24VDC,45V~DC150V For 36VD,60V~DC150V For 48VDC |
System Max. PV Power | 12V | 960W | 1200W |
24V | 1920W | 2400W |
36V | 2880W | 3600W |
48V | 3840W | 4800W |
Low Voltage Input Protection | DC22V for 12V system,DC34V for 24V ,DC50V for 36V ,DC65V for 48V |
Low Voltage Input Recovery | DC145V for 12V/24V/36V/48V system |
Max DC Voltage | 150VDC |
Overvoltage Protection | 150VDC |
Overvoltage Recovery | DC145V |
Conversion Efficiency | ≥96.5%,≤99% |
Display | LCD display | PV VDC, Charge Amp WH , BAT VDC % , Load Amp W, Charging Mode,Time , setup , Fault info |
LED display | 3 LEDs:Fault,charge,power |
Communication | With RS232 COM Communication and LAN port IP and TCP communication |
Discharge Mode | Double-time control,ON / OFF mode,PV voltage control,PV voltage / time delay control |
Protection | Input Low Voltage/Overvoltage/ Polarity Reversal/Protection |
Output Overvoltage /Polarity ReversalProtection |
Short-circuit Protection,Recover after eliminating |
Over Temperature Protection,95ºC |
Physical | Product size | D420*W280*H102 mm |
Packing size | D500*W360*H195 mm |
G.N/N.G(kg) | 8.5/7.1 |
IP Grade | IP50 |