Medical Equipment Hospital Fully Automatic Vet Clinical Chemistry Analyzer

Min.Order: 1
Product origin: Guangzhou, Guangdong, China
Infringement complaint: complaintComplaint
US$ -1

Description
YSTE161V Fully Automatic Vet Clinical Chemistry Analyzer




Model: YSTE161V

Application:
Biochemistry Analyzer is designed for vet clinic or laboratory to measure the quantity of chemical or biochemical components in animal serum, urine and other liquid sample, used to test liver function, kidney function, cardiac markers, blood sugar, blood lipid, etc.

 
Technical Specifications:
 Analytical System Fully automatic, Random Access
 Method End point, Rate, Fixed time, Immunoturbidimetric, 1-2 regent, 

 Multistandard, reagent/serum blank, etc
 Assay Item 30 assay
 Throughput1 Reagent 160 tests/hr
2 Reagent 100 tests/hr
 Test Menu T.BILI, r-GT/GGT, CHO, Ca, APOB-1/B, CHE
 D.BILI, ALP/AKP, TG, CL, APOB, CREA
 TP, UREA, CK, P, CK-MB, Mg
 ALB, CREA, LDH, C, ASO, AFU
 Lactic Acid, ALT/GPT, UA, α-HBDH, CO2, FMN
 LP(a), AST/GOT, GLU, AMY, LDL-C, HDL-C
 CHE, LA, TBA, ADA, HS-CRP, PA
 Fe, Cu, Zn, C3, C4, IgG
 IgM, IgA and drug, toxicity,etc.
 Sample Position 30
 Including standard, control and STAT; either serum cup or 

 primary tube available
 Sample Volume 1~100ul, 0.1ul/step
 Reagent Position 40
 Reagent Volume R1: 1~400ul, 0.1ul/step, R2: 1~400ul, 0.1ul/step
 Reagent/Sample Probe With liquid level sensor, collision sensor,  coating and 

 automatic washing station
 Reaction Time 0~999 seconds
 Cuvette High quality uv-transmitted plastic cuvette.
 Cuvette Washing 5 channels automatic washing system for reaction cuvettes
 Probe and Mixer  

 Washing
 Independent washing station for each sample/reagent probe
 and mixer
 Alarm Automatic alarm for malfunction (eg: collision, reagent/sample
 insufficiency, full waste container, etc)
 Calibration Linear, Non-linear, Multi standard, K factor
 Sample Dilution/Retest Sample can be diluted and retested if results are out of range 

 or sample is insufficient. Also with calibrator auto diluting 

 function
 Wavelength 340-810nm
 Light Source 
 
 Halogen lamp
 Absorbance Resolution 0.0001A
 Absorbance Accuracy ±0.0003A(0-2.5A)
 Repeatability ±2%
 Quality Control Levy jennings quality control program at 3 levels
 Barcode Optional
 Printer Multiple report formats available
 System Windows XP; Windows 7
 Power Supply 220V or 110V, 50~60Hz
 Dimension 65×53×52(cm)
 Weight 45kg


Features:
Random access fully automatic biochemistry analyzer
New concept and more friendly software
Automatic washing station for both sample and reagent probe
Liquid level detection and collision protection for both sample and reagent probe
Reliable cooling system for reagent chamber
Powerful reaction cuvette washing system barcode scanner (optional)
Lower waste and pro-environment

Structure:
1. Optical System
Light source: Halogen-tungsten lamp, 2000hours working life about
Wavelength: 340nm-810nm
Linear range:0~3ABS

2. Sample System
a) Sample tray: 30 sample position, available to use serum cup or blood tube
b) Sample volume:1~100ul, programmed by 0.1ul step
c) Sample probe: Liquid level detection and collision protection automatically
d) Probe cleaning: automatic washing both inside and outside, Carryover<0.1%
e) Automatic sample dilution

3. Reagent System
a) Reagent tray: 40 positions for single &dual Reagents.
b) Refrigeration: Refrigerated reagent
c) Compartment 24h Cooling system maintaining temperature 2~8°C
d) Reagent volume:1~400ul, programmed by 0.1ul step
e) Reagent probe: Liquid level detection and collision protection automatically
f) Pre-heating function.
g) Real-time monitoring of reagent volume and auto alarm
h) Probe cleaning: automatic washing both inside and outside, Carry over<0.1%

4. Reaction System
a) Reaction tray: 60 reaction cuvettes, High quality UV-transmitted plastic cuvettes adopt
b) Back-Dividing-Light technology
c) Min Reaction volume: 200ul
d) Reaction Temperature:37°C+0.1°C
e) Mixing system: Independent mixing probe
f) Automatic washing cuvettes

5. Washing System
a) Automatic cleaning Sample/mixer probe
b) Five channels washing station for each cuvette
c) Automatic record and deduct cuvette blank value

6. Operation Unit
Operation system: Windows XP or WIN 7
Interface: RS-232

7. Working Conditions
a) Power Supply: 220V±10%, 50/60HZ; 110V (optional)
b) Power consumption: ≤1200VA
c) Temperature:15~30°C
d) Humidity: ≤85%
e) Water consumption: 4L/h

one-stop shopping
medical veterinary clinic
 veterinary equipment
x ray roomx ray machine
processor
x ray film
cassette
Intensifying screen
lead clothings(lead glove, lead glasses,
lead cap, lead apron, lead collar)
ultrasoundb/w 2D ultrasound
2/3/4D color ultrasound
laboratory roomchemistry analyzer
hematology analyzer
microplate elisa reader
microplate washer
centrifuge
pipette
water bath
urine analyzer
operation roompatient monitor
ECG
oxygen generator
operating lamp
operation table
medical drill and saw
ventilator
anesthesia machine
infusion pump
oxygen supply cage
bath tub
electric suction device
portable autoclave sterilizer

Product Tag:
Related categories: