Weighbridge Load Cell Czl111

Min.Order: 1
Product origin: Dongguan, Guangdong, China
Infringement complaint: complaintComplaint
US$ 50

Description
Rated Load(t): 3,4,5

Main Features: Alloy steel & stainless structure; bellows hermetically sealed by laser, nickel plated, waterproof and anti-corrosion, suitable for multiform environments; suitable for electronic platform scales, hopper scales, and other electronic weighing devies. 
 
Parameters
Precison : C1 Temp. effect on span(%F.S/10°C): ±0.03
Comprehensive error(%F.S) : ±0.05 Temp. effect on zero(%F.S/10°C): ±0.05
Rated output(mv/v) : 2.0±0.002 Compensated temp. range(°C ) : -10~+40
Creep(%F.S/30min) : ±0.03 Use temp. range(°C ) : -20~+55
Zero balance(%F.S) : ±1.0 Excitation voltage(V) : 10(DC)
Input resistance(Ω) : 700±10 Safe overload (%F.S) : 120
Output resistance(Ω) : 700±5 Ultimate overload (%F.S) : 150
Insulation resistance(MΩ) : ≥5000(100VDC) Defend grade : IP66

Installation size (mm):
220x86

Wiring schematic diagram: 
Red: Input ( + )    White: Output ( - )
Black: Input ( - )    Green: Output ( + ) 

Notes:It used 6-core shielded cable(φ5×12000mm)