Manual Synchronized Asynchronized Monophaisc Defibrillator

Min.Order: 1
Product origin: Guangzhou, Guangdong, China
Infringement complaint: complaintComplaint
US$ 1999 ~ 3555

Description

Manual Synchronized Asynchronized Monophaisc Defibrillator
Model:MC-9000C

Product Description

Defi-Monitor is used to monitor patient's physiological parameters such as ECG,RESP,SpO2,NIBP,DEFI and TEMP continuously. It is intended to be used in various hospital rooms such as Coronary Care Unit,Intensive Care Unit,Neonatal Intensive Care Unit and Operating Room to provide additional information to medical and nursing staff about the physiological condition of the patient.
It is not intended to be used in outdoor transport applications.

Specification

What is detail of our monophaisc defibrillator? 

Defibrillator typeManual, Synchronized, Asynchronized 
Out put waveform                                           Monophasic technology
Energy accuracy ∠+1%
Energy selection0, 20, 50, 100, 160, 250, 300, 360 joule (nominal at a resistance of 50)
Charging timeMaximum 8 seconds to 360 Joules
Standard Adult/Pediatric Paddles Reusable external adult paddles(pediatric paddles integrated)
Power requirements(a)AC Power supply:110V, 60 Hz /220V,50 Hz 
(b)Vehicle Voltage:DC 12V
Internal Battery Backup(1)Battery type:Rechargeable lead-acid battery
(2)Charging time:Time-Minimum of 4 hours for full charging   
(3)Battery charging:During AC Power Supply operation of the device.
(4)Charging /Low Battery Indication:Red LED               
(5) Battery Capacity:100% of the battery will provide 120 mins of monitoring;and 30 discharges at 360 joules.
DisplayHigh resolution true-color graphic LED Dimensions  10'diagonal
ECGECG lead: 1.2.3 AVR, AVL, AVF, V1~V6, GND S-T segment analysis: -2.0~2.0mv Arrhythmia analysis: yes Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation
RespirationMeasurement method: Thoracic impedance
NIBPWorking mode: Manual/Automatic/stat(5 minutes)
Method: Automatic oscillation
Cuff type: standard Adult; optional Pediatric/Neonatal
TemperatureMeasurement range 20~45ºC
Resolution 0.1ºC
Pulse Oximetry(spO2)Display : spo2 value, pulse histogram, waveform, Pulse
Range:  0~99%for adult, pediatric and neonatal patients
Probe : standard adult finger clip
optional pediatric Y-type clip and neonatal wrap
Pulse range Pulse range: 0-255bpm

 

What is configuration of our manual defibrillator? 

Standard parameter & configurationECG/ RESP,/SPO2,/TEMP,/PR,/NIBP/DEFIBRILLATOR
Optional parameter1. Recorder
2. Change be change to lithium battery.
Main unitDesktop
DimensionsL410xW360xH260 mm
Weight13kg