Stm1-63 4p MCB Circuit Breaker High Breaking Capacity Overload Protection

Min.Order: 1,000
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 2.12 ~ 2.2

Description
Product Description

GENERAL
  STM1-63 series high breaking capacity mini circuit breaker is used in AC50/60Hz, rated voltage of 230V3, 4 poles 400V, rated current to 63A for overload and short-circuit protection as well as for unfrequented switching under normal case.It is used extensively for industry, commercial and household.This product conform to IEC60898 standard.

Specification:

ModelSTM1-63 MCB
Pole1P,2P,3P,4P
Rated Current(In)1,2,4,6,10,16,20,25,32,40,50,63A
Rated Voltage(Un)AC230(240)/400(415)V
Rated Frequency50/60HZ
Tripping curveB,C,D
Magnetic releasesB curve: between 3and 5 In
C curve: between 5and 10In
D curve: between 10 and 14In
Electro-mechanical enduranceover 6000 cycles

 1. Application:For protecting cables and equipments against overload and short circuit.
2. General rules for choosing MCB.
a. Technical data of the network at the point considered
The earthing systems,short-circuit current at the circuit breaker installation point,which must always be less than the breaking capacity of this device,network normal voltage.
b. There are 3 curvve characteristics for magnetic operation:
B curve (3-5In) protection and control of the circuits against length cables in TN and IT systems.
C curve (5-10In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
D curve (10-14In) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers,breakdown lamps.)

 Standard IEC/EN  60898-1
Electrical
features
Rated current InA1,2,4,6,10,16,20,25,32,40,50,63
PolesP1,2,3,4
Rated voltage UeVAC  240/415
Insulation voltage UiV500
Rated frequencyHz50/60
Rated breaking capacityA45,006,000
Rated impulse withstand voltage(1.2/50)UimpV4000
Dielectric test voltage at ind.Freq.for 1 minKv2
Pollution degree 2
Thermo-magnetic release characteristic B,C,D
Mechanical
features
Electrical lifet4000
Mechanical lifet10000
Protection degree IP20
Reference temperature for setting
of thermal element
ºC30
Ambient temperature
(with daily average ≤35ºC)
ºC-5~+40(Special application please refer to
temperature compensation correction)
Storage temperatureºC-25~+70
InstallationTerminal connection type Cable/Pin-type busbar
Terminal size top/bottom for cablemm225
AWG18-3
Therminal size top/bottom for busbarmm225
AWG18-3
Tightening torqueN*m2
In-lbs18
Mounting on DIN rail EN 60715(35mm)by means of fast clip device
Connection From top and bottom


Our Services:

  1. Competitive price
  2. Continuance Service and support
  3. Good-after service
  4. Quality Reliability and Long Product Life.
FAQ:
1. What's the difference between type C and type D miniature circuit breaker?

A: type C is mainly used for power distribution control and lighting protection.type D is mainly used for motor protection.

2. How to calculate the ampere number formula?
A: it is known that the power divided by voltage is equal to the ampere (WN=A).

3. What is the difference between unipolar, bipolar and tripolar?
Answer: single pole (1P)220V cut off live wire, bipolar (2P)220V live wire and zero line colleagues cut off, three levels (3P)380V three-phase power all cut off

4. What is the meaning of the circuit breaker (C6, C10, C25, C32, C63, etc.)?
A: air switch c is the classification of circuit breakers, and the number represents the number A of circuit breakers.

5. How to select the right circuit breaker?
Answer: when choosing circuit breaker, should choose than the circuit breaker of electric current small. If the BV2.5 square wire bearing current is 26A, the circuit breaker should be selected below 25A.

Product Tag:
Related categories:
Scroll to Top