CE, TUV Photovoltaic 500V 2p DC Surge Protective Device SPD

Min.Order: 1
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 5 ~ 8

Description
Our comapny can supply free sample for you to test if you are the first time to use our producst.
solar surge protector          XLSPD-PV              
PV DC specific (LEC 6614-1/EN 61643-11)
Pole2 pole3 pole
Electrical Parameter
Classifical testIIII
Uoc max (V DC)5506008001000
Uc (V DC)55060010001000
In(8/20)us (KA)2020
Imax(8/20)us (KA)4040
Up (KV)23.8
Remote control and indication
Indication window
Plug-in module
Remote signal contact
Remote signal contactMax working volt250V AC/30V DC250V AC/30V DC
Max working amp 1A (250V/AC)1A (250V/AC)1A (250V/AC)
1A (30V DC)1A (30V DC)1A (30V DC)
Wiring & installation
Wiring capacity(mm2)Hard wire4-25mm4-25mm
 Flexible wire4-16mm4-16mm
Stripping length 1010
Terminal screwaM5M5
Torque(Nm)Main ciruit3.53.5
Remote signal contact0.250.25
Protection classAll profileIP40IP40
Connection portIP20IP20
Installation environmentNo obvious shock and vibration
Altitude(m)≤ 2000≤ 2000
Working temperature6767
Relative humidity30%-90%30%-90%
How to installInstall with H35-7.5/DIN35 stell mounting rail
Size(mm) (W*H*L)W3654
H9090
L48.548.5
Weight (KG)0.280.42
Nominal PV system volt600V800V1000V
MCOV(UCPV)700V DC1170V DC1200V DC
Max system discharge Current  (8/20us) (Imax)40KA40KA30KA
Volt protection leve (UP)≤ 2.5KV≤ 4.0KV≤ 4.5KV
Volt protection Level at 5KA (UP)≤ 2.0KV≤ 3.5KV≤ 4.0KV
Integrate fuse breaking capacity/interrupting rating30KA/800V DC30KA/1000V DC30KA/1200V DC
TechnologyShort-circuit interruption (SCI) overcurrent protection
Operating temperature range-40 to +80
Nominal discharge current12.5KA
Response time (ta)<25ns
Operating state/fault indicationGreen (good) / Red (replace)
Mounting 35mm DIN Rail per EN 60715
Degree protectionIP20
capacity3 modules DIN 43880








Product Tag:
Related categories:
Scroll to Top