10kw, 30kw, 50kw, 60kw, 100kw Natural Gas Generator Set, Biomass Power Generator

Min.Order: 1
Product origin: Ningde, Fujian, China
Infringement complaint: complaintComplaint
US$ 3000 ~ 4000

Description


Genset working condition:
lAcceptable working conditions:
Ambient temperature : -10°C~+40°C
(antifreeze and water heater needed for below 0°C)
Relative humidity:< 90% (20°C)
Altitude:≤ 500m
 
l Normal working conditions:
Genset can run at rated power on the conditions:
Atmospheric Pressure: 100kPa, Ambient Temp: 20°C, Relative Humidity: 30%.
 
lApplied gas:
 Natural Gas, Biogas, LPG, Landfill gas, Oil gas, Syngas, Coal mine gas
 Acceptable fuel gas pressure: 8~12kPa

CH4 content: for natural gas≥85% CH4 content: for biogas≥55%
Gas heat value≥5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel(Heat value<5500kcal/Nm3, it will lower the power efficiency.
Gas doesn't include free water or free materials (the size of impurities should be less than 5μm.)
H2S content≤200mg/Nm3
NH3 content≤20mg/Nm3
Impurities content≤30mg/Nm3;size≤5μm
Water content≤40g/Nm3, no free water.

 

Engine of CUMMINS EG120 Natural Gas Generator Set 

Engine ModelCUMMINS 6CT
Type6 cylinders in line
Bore * Stroke (mm)114*134
Displacement(L)8.3
Compression ratio10.5:1
Rated speed(rpm)1500/1800
Inlet typeExhaust Turbocharger/Air-Air Intercooler
Cooling typeCooling water tank
Fuel SystemLow and high pressure
ESC TypeSpecial for U.S. GAC natural gas
Ignition sequence1-5-3-6-2-4
The allowed maximum speed (Natural gas supply closed at this time)2160 rpm
The allowed maximum rotating speed (The ignition system shut down at this time)2160 rpm
Oil Capacity23.8 L
Cooling water capacity24.3 L
Maximum engine back pressure10.2 kpa
Gas consumption(m3kw·h)<0.3
Rough oil consumption(g/kWh)<1.2
Radiator and oil cooler heat40KW
Exhaust pipe heat radiation46KW
Engine thermal radiation8KW
Alternator thermal radiation2KW
Cooling water temperature95 Deg C
Oil temperature<120 Deg C
Exhaust pipe heat energy (above 120 º C section)110KW
Exhaust temperature (before vortex )650±15 Deg C
Exhaust Flow1050 m³/h
Fan exhaust flow7 m³/s
Noise level from 1 m less than 100 db(A)
  

Alternator of CUMMINS EG120 Natural Gas Generator Set

Alternator ModelEngga EG225L-120N
Excitation MethodBrushless Permanent Magnet
Winding pitch2/3 pitch
Number of poles4
Bearing number1
Stator Windings12 ends
Insulation ClassH class
Protection classIP 21 or IP 23
Load typeContinuous operation
AVR ModelWT-2
AlignmentFly wheel
Temperature RangeLess than 125 degrees Celsius
Overload  Capacity- the percentage of rated power110%
Waveform distortion rate, no-load<5%
Voltage Regulation ModeAVR
Voltage Regulation Range±5%
Steady State Voltage Regulation±1%
No-load line voltage sine wave distortion<2%
Telephone interference factor (TIF)< 50
  

CUMMINS EG120 Natural Gas Generator Set 

Rated Output(KW)120
Standby Output(KW)132
Voltage(V)400
Current(A)216
Size(mm)2500*950*1535
Approximate weight(KG)1400
Emission levels (Nox)Euro II emission(mg/m³)
Naturally aspirated engine intake air temperatureNone
Air temperature before entering the air to air intercooler  82-87(Deg C)
Air temperature after entering the air to air intercooler  35-42(Deg C)
Rated Power @ 0.8 power factor (w / pump s and w / o fan)120KW (continuous operation)
Total energy input (100% load)332(KW)
Electrical efficiency36.20%
Thermal efficiency87.90%
Control panel(Deepsea or others)Synchronizing Control, Multilingual Mode Digital Control, Diagnostic Function, Direct Text Indicate of Faults, MOBUS Communication Protocol, Compatible Communication, Exchange Telecommunications,  Wired Control Data Output, Automatic or manual start



NATURAL GAS generator Set
Technical Data      
Genset ModelPrime Power (KW/KVA)Engine ModelClylindersBore×Stroke (mm)Gas Consumption Rate (m3/kw.h)Displacement (L)
KWKVA
NG2-30KW3037.51004NG4100×1270.5-0.33.99
NG2-40KW40501006NG6100×1270.5-0.35.98
NG2-90KW90112.51006-G6TAG6100×1270.5-0.35.98
NG2-100KW100110R6156126×1300.5-0.39.7
NG2-120KW120132R6156126×1300.5-0.39.7
NG2-150KW150165R6186126×1500.5-0.311.2
NG2-160KW160200D116128×1420.5-0.310.96
NG2-220KW220275D158128×1420.5-0.314.62
NG2-320KW320400D2212128×1420.5-0.321.93
NG2-440KW440500D3016128×1420.5-0.329.24

2.Genset working condition :
ACCEPTABLE WORKING CONDITIONS: 
Ambient temperature : -40°C~+45°C 
(antifreeze or hot water needed for below -20°C) 
Relative humidity:<90%(20°C)
Altitude:≤1000m
NORMAL WORKING CONDITIONS: 
Genset can run at rated power on the conditions: 
Atmospheric Pressure: 100kPa
 Ambient Temp: 20°C
Relative Humidity30%.
APPLIED GAS:Natural Gas, Biogas,Oil field gas
Acceptable gas pipeline pressure:0.8~450kPa
Engine inlet pressure: 0.8~5.0kPa (80~500mmH2O) 
CH4 content:for natural gas ≥75%; for biogas≥40%
Sulphur content:≤400ppm
Gas heat value:≥5500kcal/Nm3 (23MJ/Nm3 )
Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel(Heat value<5500kcal/Nm3, it will lower the power efficiency.Gas doesn't include free water or free materials (the size of impurities should be less than 5μm.)
 
3 Standard Scope of Supply:
1. Brand new gas engine, 90% parts include engine body , crank shaft, cam shaft, piston, cylinder head, etc made by Cummins with best quality
2. Brand new brushless France Leroy Somer alternator
3. Rating: 3 phases 4 lines. 400/230V, 50 HZ , 1500rpm, 0.8PF, IP22-23, Insulation class H
4. Radiator for 40°C/50°C ambient temperature
5. Ignition system adopted USA ALTRONIC
6. Emergency stop mounted
7. Battery,Battery cable and Battery charger
8. Standard tool box
9. Standard Accessory for installation (include bellows,silencer,flange,asbestos pad,Anti-rust water,screw )
10. Gas Train include Regulator valve,Electromagnetic Valve, Fire arrestor,Ball Valve (Chinese brand)
11. Testing report and maintenance manual.
 
 
 Hebe Wang 

FUJIAN XINYABO POWER TECHNOLOGY CO.,LTD |  Tiehu  industrial area,Fuan city,Fujian province,China
 
 

Product Tag:
Related categories:
Scroll to Top