Genset working condition:
lAcceptable working conditions:
Ambient temperature : -10°C~+40°C
(antifreeze and water heater needed for below 0°C)
Relative humidity:< 90% (20°C)
Altitude:≤ 500m
 
l Normal working conditions:
Genset can run at rated power on the conditions:
Atmospheric Pressure: 100kPa, Ambient Temp: 20°C, Relative Humidity: 30%.
 
lApplied gas:
 Natural Gas, Biogas, LPG, Landfill gas, Oil gas, Syngas, Coal mine gas
 Acceptable fuel gas pressure: 8~12kPa

CH4 content: for natural gas≥85% CH4 content: for biogas≥55%
Gas heat value≥5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel(Heat value<5500kcal/Nm3, it will lower the power efficiency.
Gas doesn't include free water or free materials (the size of impurities should be less than 5μm.)
H2S content≤200mg/Nm3
NH3 content≤20mg/Nm3
Impurities content≤30mg/Nm3;size≤5μm
Water content≤40g/Nm3, no free water.

NATURAL GAS generator Set
Technical Data      
Genset ModelPrime Power (KW/KVA)Engine ModelClylindersBore×Stroke (mm)Gas Consumption Rate (m3/kw.h)Displacement (L)
KWKVA
NG2-30KW3037.51004NG4100×1270.5-0.33.99
NG2-40KW40501006NG6100×1270.5-0.35.98
NG2-90KW90112.51006-G6TAG6100×1270.5-0.35.98
NG2-100KW100110R6156126×1300.5-0.39.7
NG2-120KW120132R6156126×1300.5-0.39.7
NG2-150KW150165R6186126×1500.5-0.311.2
NG2-160KW160200D116128×1420.5-0.310.96
NG2-220KW220275D158128×1420.5-0.314.62
NG2-320KW320400D2212128×1420.5-0.321.93
NG2-440KW440500D3016128×1420.5-0.329.24

2.Genset working condition :
ACCEPTABLE WORKING CONDITIONS: 
Ambient temperature : -40°C~+45°C 
(antifreeze or hot water needed for below -20°C) 
Relative humidity:<90%(20°C)
Altitude:≤1000m
NORMAL WORKING CONDITIONS: 
Genset can run at rated power on the conditions: 
Atmospheric Pressure: 100kPa
 Ambient Temp: 20°C
Relative Humidity30%.
APPLIED GAS:Natural Gas, Biogas,Oil field gas
Acceptable gas pipeline pressure:0.8~450kPa
Engine inlet pressure: 0.8~5.0kPa (80~500mmH2O) 
CH4 content:for natural gas ≥75%; for biogas≥40%
Sulphur content:≤400ppm
Gas heat value:≥5500kcal/Nm3 (23MJ/Nm3 )
Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel(Heat value<5500kcal/Nm3, it will lower the power efficiency.Gas doesn't include free water or free materials (the size of impurities should be less than 5μm.)
 
3 Standard Scope of Supply:
1. Brand new gas engine, 90% parts include engine body , crank shaft, cam shaft, piston, cylinder head, etc made by Cummins with best quality
2. Brand new brushless France Leroy Somer alternator
3. Rating: 3 phases 4 lines. 400/230V, 50 HZ , 1500rpm, 0.8PF, IP22-23, Insulation class H
4. Radiator for 40°C/50°C ambient temperature
5. Ignition system adopted USA ALTRONIC
6. Emergency stop mounted
7. Battery,Battery cable and Battery charger
8. Standard tool box
9. Standard Accessory for installation (include bellows,silencer,flange,asbestos pad,Anti-rust water,screw )
10. Gas Train include Regulator valve,Electromagnetic Valve, Fire arrestor,Ball Valve (Chinese brand)
11. Testing report and maintenance manual.
 

120kW natural gas generator

Product Description

 1.Generator set parameter

Model

120GFT

Rated power

120kW/150kVA

Basics electric parameter

50/60Hz,3 p 4 w,440V/230V

Rated speed

1500/1800rpm

Power factor

Lag0.8

Insulation Class

H

Protection Class

IP23

Gross Weight

1950KG

Dimension(L*W*H)

2850*1000*1750mm

 

2.Engine parameter 

Engine Model

NC83D14TL

Cylinder Qty

L6

Rated power

140kW

Bore*Stroke

114*135mm

Rated Speed

1500/1800rpm

Displacement

8.3L

Fuel gas intake pressure

2kPa--50kPa

Fuel gas type

Natural gas

Engine Type

V type 4 stroke, electric control ignition,Pre-mixed stoichiometryburn

 

3.Alternator parameter 

Brand

MBH( Germany)

Rated Frequency

50/60Hz

Model

XN274FS

Rated output

400V/230V

Rated Power

120kW/150kVA

Exciting Mode

Self-Excited,Brushless

Rated current

216A

Voltage Regulation

AVR

 

4.Genset Controller introduction 

Main Protection Function

Main Displayed Parameter

Fail to start

Over speed

L-L&L-N voltage

Speed and running hours

Low engine oil pressure

High engine temperature

Rated outputload current

Engine oil temperature

Generator low frequency

Generator high frequency

Frequency

Engine oil pressure

Generator low voltage

Generator high voltage

Load power

Coolant temperature

 
 