No. | Name | Parameter |
1 | Smelting equipment | Induction furnace |
2 | Capacity | 30T |
3 | Quantity | 3 sets |
No | Item | Unit | Design index | Index or policy | |
Index | Policy | ||||
Dust capture rate | % | ≥95 | There is no yellow smoke outside the roof | ||
Amount of dust collecting | kg/T | ≥10 | |||
emission | mg/Nm3 | ≤40 | <50 | ||
collection efficiency | % | >95 | |||
Job dust | mg/m3 | <10 | <10 | Hygienic Standards for the Design of Industrial Enterprises |
No | Item | Unit | 30T induction furnace |
1 | Quantity | Set | 3 |
2 | Capture method method | Semi-airtight housing | |
3 | System exhaust capacity | m3/h | 500000 |
4 | System resistance | Pa | 4200 |
5 | Velocity in the pipeline | M/s | 16-19 |
6 | Main air blower | Y4 -73No.27D /730 rpm | |
7 | Main drive motor | Y560L1-8/800KW/10V | |
8 | Blower startup | Frequency converter 800KW/10KV | |
9 | Filter area | M2 | 6500 |
10 | Filtration velocity | M/min | ~1.3 |
11 | Pressure of compressed air | MPa | >=0.4 |
12 | Compressed air consumption | NM3/min | 4 |
13 |
| mm | Φ3200 |
14 | Chimney diameter×H | mm×m | Φ4000×2 |