Usun Model: Stv15-Dn200-Mpc 15MPa Portable Manual Control Air Pressure Test Bench for Relief or Safety Valve

Min.Order: 1
Product origin: Dongguan, Guangdong, China
Infringement complaint: complaintComplaint
US$ 5000 ~ 7000

Description
Model :STV15-DN200-MPC Maximum 15 MPA portable air pressure test bench for safety valve or relief valve 




1 .Introduction
 
The safety valve test bench is a new type of pressure test device developed by our company for reference to GB/T 12242-2005 (pressure
 
 
release   device and performance test specification), which is used to adjust and test the setting pressure of the safety valve.

 

2, Function

 
The safety valve test bench can do the whole pressure test, the discharge pressure test, the back seat pressure test and the pressure safety
 
performance of various relief valves.

 

 3. System composition


It consists mainly of high pressure power system, clamping device system,  and so on 

1). power system(High-pressure power source).

 
Air driven gas booster pump- GBT25 air driven gas booster pump 
 
Driven air pressure: 3-8bar;
 
Output gas/air pressure 0-150bar;
 
Test medium: air, nitrogen

 2). Clamping system:


The power of the clamping device is provided by a manual hydraulic(oil) pump to provide clamping pressure
 
,Valve diameter range:DN15-DN200 



Technical specification for GBT  seriel air gas booster pump inside of stainless steel frame

 

Model

Pressure boost ratio

Min. gas

Inlet pressure

PA (bar)

Max.gas

Inlet pressure

PA (bar)

Max. gas

outlet pressure PB (bar)

 

Driven air pressure  PL

Formula to

calculate gas outlet pressure PB

Connection:

Gas Inlet /

Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

GBT25

25:1

1

10

200

 

3-8 bar

25XPL+3.5XPA

3/8/ 1/4

136(at PAof 8 bar )

GBT40

40:1

1

10

320

 

3-8 bar

40XPL+ 6XPA

3/8/ 1/4

124(at PAof 8 bar )

 GBT60

10:1/60:1

1

10

480

3-8 bar

60XPL+6X PA

3/8/ 1/4

84(at PAof 8 bar )

GBT25/60

25:1/60:1

10

25

480

 

3-8 bar

60XPL+2.5XPA

3/8/ 1/4

80(at PAof 15 bar )

GBT100

100:1

1

10

800

3-8 bar

100XPL+10XPA

3/8/ M14*1.5

63(at PAof 8 bar )

 

  Note:  PLdriven air pressure   PA: gas inlet pressure   PB: gas outlet pressure    In order to extend the lifetime of

the pump,

           the driven air   pressure should not be higher than 8 bar

Main components included in this portable air pressure safety

valve test bench


Typical layout  drawing for clamping device 




Typical circuit of such portable safety valve test bench 



 



Factory corners 


 
Product Tag:
Related categories:
Scroll to Top