250kVA Biogas / Natural Gas Generator

Min.Order: 1
Product origin: Ningde, Fujian, China
Infringement complaint: complaintComplaint
US$ 3000 ~ 4000

Description


Genset working condition:
lAcceptable working conditions:
Ambient temperature : -10°C~+40°C
(antifreeze and water heater needed for below 0°C)
Relative humidity:< 90% (20°C)
Altitude:≤ 500m
 
l Normal working conditions:
Genset can run at rated power on the conditions:
Atmospheric Pressure: 100kPa, Ambient Temp: 20°C, Relative Humidity: 30%.
 
lApplied gas:
 Natural Gas, Biogas, LPG, Landfill gas, Oil gas, Syngas, Coal mine gas
 Acceptable fuel gas pressure: 8~12kPa

CH4 content: for natural gas≥85% CH4 content: for biogas≥55%
Gas heat value≥5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel(Heat value<5500kcal/Nm3, it will lower the power efficiency.
Gas doesn't include free water or free materials (the size of impurities should be less than 5μm.)
H2S content≤200mg/Nm3
NH3 content≤20mg/Nm3
Impurities content≤30mg/Nm3;size≤5μm
Water content≤40g/Nm3, no free water.

NATURAL GAS generator Set
Technical Data      
Genset ModelPrime Power (KW/KVA)Engine ModelClylindersBore×Stroke (mm)Gas Consumption Rate (m3/kw.h)Displacement (L)
KWKVA
NG2-30KW3037.51004NG4100×1270.5-0.33.99
NG2-40KW40501006NG6100×1270.5-0.35.98
NG2-90KW90112.51006-G6TAG6100×1270.5-0.35.98
NG2-100KW100110R6156126×1300.5-0.39.7
NG2-120KW120132R6156126×1300.5-0.39.7
NG2-150KW150165R6186126×1500.5-0.311.2
NG2-160KW160200D116128×1420.5-0.310.96
NG2-220KW220275D158128×1420.5-0.314.62
NG2-320KW320400D2212128×1420.5-0.321.93
NG2-440KW440500D3016128×1420.5-0.329.24

2.Genset working condition :
ACCEPTABLE WORKING CONDITIONS: 
Ambient temperature : -40°C~+45°C 
(antifreeze or hot water needed for below -20°C) 
Relative humidity:<90%(20°C)
Altitude:≤1000m
NORMAL WORKING CONDITIONS: 
Genset can run at rated power on the conditions: 
Atmospheric Pressure: 100kPa
 Ambient Temp: 20°C
Relative Humidity30%.
APPLIED GAS:Natural Gas, Biogas,Oil field gas
Acceptable gas pipeline pressure:0.8~450kPa
Engine inlet pressure: 0.8~5.0kPa (80~500mmH2O) 
CH4 content:for natural gas ≥75%; for biogas≥40%
Sulphur content:≤400ppm
Gas heat value:≥5500kcal/Nm3 (23MJ/Nm3 )
Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel(Heat value<5500kcal/Nm3, it will lower the power efficiency.Gas doesn't include free water or free materials (the size of impurities should be less than 5μm.)
 
3 Standard Scope of Supply:
1. Brand new gas engine, 90% parts include engine body , crank shaft, cam shaft, piston, cylinder head, etc made by Cummins with best quality
2. Brand new brushless France Leroy Somer alternator
3. Rating: 3 phases 4 lines. 400/230V, 50 HZ , 1500rpm, 0.8PF, IP22-23, Insulation class H
4. Radiator for 40°C/50°C ambient temperature
5. Ignition system adopted USA ALTRONIC
6. Emergency stop mounted
7. Battery,Battery cable and Battery charger
8. Standard tool box
9. Standard Accessory for installation (include bellows,silencer,flange,asbestos pad,Anti-rust water,screw )
10. Gas Train include Regulator valve,Electromagnetic Valve, Fire arrestor,Ball Valve (Chinese brand)
11. Testing report and maintenance manual.
 