Description
CHILLER
WATER-COOLED and AIR-COOLED
APPLICATION
Plastic, electronics manufacturing, electroplating, food, medical, chemical, printing, laser, machining and other industries.
FEATURES
• Japan Panasonic compressor, high efficiency, low noise, quiet operation
• Emerson imported refrigeration accessories with stable performance
• High efficiency evaporator and condenser, save energy by more than 30%
• The electrical parts are all genuine Siemens from Germany, ensuring stable operation of the machine.
• All pipeline insulation design to prevent local convection of the body pipeline
• Built-in automatic water supply device with box evaporator
SAFETY SYSTEM
• Compressor overload protection
• Pump overload protection
• Poor heat dissipation protection
• Insufficient refrigerant protection
• Refrigerant shortage protective
• High voltage protection
• Low voltage protection
• Power reverse phase loss phase protection
• Fault alarm buzzer
TECHNICAL PARAMETER
WATER-COOLED CHILLER
Model
HTC5W
HTC8W
HTC10W
HTC12W
HTC15W
HTC20W
HTC25W
HTC30W
HTC40W
HTC50W
Cooling Capacity
kW/h
50Hz
60Hz
15
18
24
28
30
36
34
41
49
58
61
72
68
82
97
116
122
146
137
164
Kcal/h
50Hz
60Hz
12900
15394
20296
24338
25800
30960
29412
35260
41710
50052
52460
62092
58738
70606
83420
100104
104920
125904
117476
140972
Input Power
kW
5
8
10
11
15
20
22
31
39
49
Voltage
3PH-380V-50Hz (Or 200V/220V/415V 50Hz/60Hz)
Refrigerant
Name
R22 (Or R134a/R407c)
Control Method
Externally balanced thermal expansion valve
Compressor
Type
Hermetic gyral type
(KW) Power
3.73
5.97
7.46
8.95
11.19
14.92
18.64
22.38
29.84
37.28
Evaporator
Type
Water tank with coil
(m³/h)
Chilled Water
2.6
3.2
4.1
4.9
5.2
6.2
5.9
7.1
8.4
10.0
10.0
12.1
11.8
14.1
16.7
20.0
20.6
24.7
23.5
28.2
(L)
Water Tank
50
120
120
160
200
250
250
265
330
350
(Inch)
Water Pipe
1
1- 1/ 2
1- 1/ 2
2
2
2-1/2
2- 1/ 2
2- 1/ 2
3
3
Condenser
Type
Copper tube high efficiency shell and tube type
(m³/h)
Cooling Water
3.5
4.2
5.2
6.1
6.8
7.4
7.9
9.3
10.7
11.7
13.9
16.3
15.8
18.6
20.5
22.7
27.8
33.4
31.6
37.9
(Inch) Water Pipe
1-1/2
1-1/2
1-1/2
1-1/2
2
2
2-1/2
3
3
3
Pump
(kW) Power
0.37
0.75
0.75
0.75
1.5
2.25
2.25
2.25
3.75
4.5
Head, H (m)
20
22
22
22
24
30
30
30
40
52
Dimensions
L (MM)
1070
1300
1300
1300
1535
1835
1835
1880
2100
2200
W (MM)
600
710
710
710
800
800
800
910
1100
1150
H (MM)
975
1390
1390
1390
1514
1514
1514
1600
1960
2100
Weight
Kg
210
300
370
430
700
750
800
950
1200
1300
Unit Conversion
1KW=860KCAL/HR
1RT=3024KCAL/HR
1BTU/HR=0.252KCAL/HR
Note:
•Working condition: Chilled water temperature range: 3°C to 35°C, temperature difference between inlet and outlet chilled water: 3°C to 8°C, cooling water temperature range: 18°C to 37°C, temperature difference between inlet and outlet cooling water: 3.5°C to 10°C
• Nominal cooling capacity calculated according to: inlet/outlet chilled fluid temperature: 12°C/7°C, inlet/outlet cooling water temperature: 30°C/35°C
• The above parameters are test results based on voltage 380V 50HZ 3-phase power, refrigerant R22 , please call staff for other parameters
• Specifications and performance are sub