Latest Portable Extracorporeal Shock Wave Therapy/Device for Rehabilitation and Physiotherapy Single End or Double End

Min.Order: 1
Product origin: Guangzhou, Guangdong, China
Infringement complaint: complaintComplaint
US$ 499 ~ 8999

Description
Mobile Shockwave Therapy Device for Physiotherapy

1 Product brief introduction
The O-Wave I is a medical device producedby Guangzhou MeCan Medical Limited , its main utilizes the energy generated by thesolenoid drive actuate bullet bodyinside therapeutic handle, sothat theimpact of the bullet bodyto pulsecolliding the therapeutic head,the acoustic pulsewill be converted tothe exact ballistic shock wave, have a good therapeutic effect for musculoskeletal disorder andother. It brings the hope to the life of skeletal muscle disease patients, pleaseread the manual carefully whenusing theproduct.
2 Product intended use
The O-wave I used in the area of adjuvant therapy of chronic joint pain and muscular pain and be usedbymedical staff
3 Primary structure of the product
Theproduct mainly consists ofhost, therapeutic handle andfoot switch, which hosts including upperandlower case, powersupply,main board andtouch screen.Accessories includepower line, handwriting pen, handle bottom case,keys andaluminium alloy suitcase. Supplies accessories includesilicone cap andtherapeutic handle/therapeutic handleand foot switch belongs to exchange component. The product structure chat is as follows:
No. Part name
1 Host
2 Energy knob
3 Handwriting pen
4 Display screen
5 Frequency knob
6 SD card slot
7 Therapeutic handle (therapeutic head)
8 Air outlet
9 Air intake and fan
10 Foot switch
11 Power switch
12 Fuse wire
13 Power port
14 Handle port
15 Foot switch port
16 Product nameplate
 


4 Product main features
Themain product featuresof O-Wave I asfollow: a) Thehumanengineeringdesignprovidessettingandoperatesconveniently; b) 7inchescolorcrystalChineseandEnglishtouchscreendesign,intuitiveandclear; c) Importpowersource,toensureinstantshockoutputeffect; d) Energyandfrequencyselection,conformtotreatmentdemand; e) Singleordualoutputisoptional,andprovidesavariousprofessionalprobe; f) Thereare7adjustablepresetreferencesolutions; g) Adoptaportabledesign.
5 Product requirements andmain parametric description
5.1Product requirements
1)Working powersupply: 100-240VAC,frequency: 50/60Hz
2)Environmental requirements
5.2Product main technical parametric description Pulse energy levels: 60-185mJ (at the applicator),freely adjustablein 10mJ increments at 22Hz max. 90 mJ at 16Hz max. 120mJ at 10Hz max. 185mJ;The output tolerance is ±40mJ,TheCV is ±5%
Working frequency 1~22Hz,adjustable in 1Hz increments
Work pattern 4continuous capture modes(shots/4/8/12 pulses)
Reference operatingversion 7preset operationversions, canbe adjustable
Suggestion for treatment parts Exceeds25preset treatment suggestion
Control function All function implemented by touching operation; rotary knob controls energy and frequency; multi-directional footswitch coordinateswith therapeutic handle operation.
Product boundarydimension
290×240×130mm(length/width/height)
Product weight 2.07kg(do not contain therapeutic handle andfootswitch)
The description of therapeutic handle/therapeutic headto shockwave The therapeutic handle design conforms to human engineering, combines anodized aluminium shell with fan cooling, produces electromagnetic force drive projectile working by means of coil electrical over. The boundary dimension is 23cm, diameter is 5cm (the maximum); the minimum service life of therapeutic handle is 2,000,000 times (the calculation according to a number of strokes); only need to do some daily maintenance and nursing for appearance, it is recommended to use cleaning with medicinal alcohol; the therapeutic head divided into 3 specifications: 6/15/25mm (diameter); the minimum service life of each therapeutic head is 150,000 times (the calculationaccordingto a number of strokes).
Power consumption 100/240VAC 50/60Hz,300VA
The fuse (wire fuse) specification 250V/10A
The requirement of therapeuticheadtemperature Theexternal temperature of therapeuticheadof the O-wave I is not greater than 48ºC.
Electrical safety classification Type BF applied parts
 