Description
HV-400B Medical Ventilator MachineProspective service and support The HV-400B ventilator is gas driven by medical compressed oxygen and compressed air. In the inspiratory phase, two streams of compressed gas (compressed oxygen and compressed air) flow into a high performance air-oxygen mixer to form a mix of oxygen and air with a certain pressure.
The automatic conversion for standby power while AC power outage, keep working not less than 1 hour.
Component Details
Display: 10.4''LCD Display Following Parameters & Real time waveform display
Operating mode and respiratory rate;
--Ventilator control frequency set by medical staff;
--Tidal volume of each breath in the patient;
--Occurrence of spontaneous breath in the patient and spontaneous breathing frequency;
--Expiratory phase and inspiratory phase and actual respiratory rate;
--Minute volume;
--Setting and adjustment of inspiration triggering pressure, PEEP, and highest airway pressure;
--Real-time variation in internal airway pressure.
Air Compressor
Power: AC220V + 22 v, 50 Hz + 1 Hz and 300 va has a good reserve of single-phase ac power supply.
FUSE: Φ 5 x 20 / F8A
Output gas pressure: 0.3 ~ 0.4 MPa
Output gas minimum flow: ≥50L/Min
Output gas transient flow: ≥100L/Min
Detailed mages: TECHNIQUES SPECIFICATIONS |
Physical specifications |
Display | 10.4'' LCD Display |
Mode | pneumatically powered and electrically controlled system |
Trolley | Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions |
Technical Specifications |
Gas requirement: | Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa |
safety valve | <12.5 kPa |
Respiratory Rate | 1 ~ 99 bpm |
Oxygen Concentration | 21% ~ 100% |
Maximum Minute ventilation | ≥18L / min |
modes of ventilation | A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT |
Ventilator compliance | ≤30 Ml/kPa |
PEEP | 0 ~ 1.0 kPa |
Ptr | -10 ~ 10 hPa |
IMV frequency | 1~20 bpm |
I/E Ratio | 4:1~1:4, Has the inverse ratio ventilation |
Tidal Volume | Setting Range: 50~1500ML Display Range: 0~2000ml ; resolution ratio: 10ml |
Inspiratory Plateau | 0~1s |
Maximum Safety Pressure | ≤ 6.0kPa |
Sigh | one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point |
Pressure limit range | 1.0~ 6.0kPa |
Airway pressure alarm: Audible and visual and with yellow and red color indicating | Lower: 0.1 kPa ~ 6.0 kPa; Upper: 0 ~ 5.0 kPa |
±0.2 kPa |
Ventilation Volume alarm | ≥ 18L/ MIN |
Power Supply Alarm | Ac/dc power supply are after failing to send out alarm immediately Alarm Time: keep >120s |
Operating conditions |
Ambient temperature | 10 ~ 40oC |
Relative humidity | no higher than 80 % |
Atmospheric pressure | 860 hPa ~ 1060 hPa |
Power requirement | 100-120 Vac, 50/60 Hz; |
Attention: the AC power supply used for the ventilator machine must be well grounded. |
Attention: the ventilator machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. |
Storage |
Ambient temperature: | -15oC ~ +50oC |
Relative humidity: | no higher than 95 % |
Atmospheric pressure: | 86 kPa ~ 106 kPa. |
It should be stored in a room without corrosive gas and well ventilated |
Package |
packaging box | comply with the requirement of GB/T 15464 |
Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation |
Moisture protection and rain protection to ensure that product is protected from natural damage. |
Safty & Alarm |
Gas source pressure | Immediate alarm; "high level alarm" indicator flickers raising an audible alarm. |
Airway Pressure Alarm | The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The "high level alarm" indicator flickers raising an audible alarm. |
Tidal Volume Alarm | Lower than 50ml, The alarm will be raised after one breathing cycle. |
Ventilation Volume Alarm | Lower: 0~12L/Min; Up: 18L/ Min |
Battery Voltage Alarm | It alrms when the battery voltage is lower than 10.5V. |
Power On Self Test | Self test before working, assure it's working normally. |
STANDARD CONFIGURATIONS |
QTY | NAME |
1 set | Main unit |
1 set | Oxygen tube |
2 set | Silicone Mask |
1 pc | Power line |
4 pcs | Threaded pipe |
2 pcs | Standard Pipe |
1 set | Oxygen Reducer |
1 set | Humidifier |
1 pc | Battery |
2 set | flow sensor |
2 pcs | A leather bag ( Blue) |
1 set | Tools with the machine |
1 set | User Manual (English Version) |