D-60b 5V 24V Industrial Dual Output Switching Power Supply

Min.Order: 1
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 5.08 ~ 7.47

Description
D-60B 5V 24V Industrial Dual Output Switching power Supply 
60W Dual Output Switching Power Supply   D-60 series
Features:
High efficiency, high reliability
Universal AC input /full range
100% full load burn-in test
Protections: Short circuit/ Over load/ Over voltage
LED indicator for power on
Cooling by free air convection
Fixed switching frequency at 54KHz
2 years warranty
SPECIFICATIONS
OUTPUT 
ModelD-60AD-60BD-60C
Output numberCH1CH2CH1CH2CH1CH2
DC Voltage5V12V5V24V15V-15V
Rated Current4A3A2A2A2.5A2.5A
Current Range0.3-6A0.2-3A0.3-2A0.2-2A0.3-3A0.2-3A
Rated Power56W58W75W
Ripple & Noise75mVp-p150mVp-p75mVp-p150mVp-p75mVp-p150mVp-p
Voltage Adj. RangeCH1: -5%,+10%CH1: -5%,+10%CH1: -5%,+10%
Voltage Tolerance±2%±6%±2%±5%±2%±5%
Setup,Rise,Hold Up Time800ms,50ms,10ms/115VAC300ms,50ms,80ms/230VACat full load
  
INPUT 
Voltage Range85~132VAC/170~264VACselected by switch47~63Hz; 240~370VDC
AC Current2A/115V1A/230V
Efficiency73%76%78%
Inrush CurrentCold start 18A/115V  36A/230V
Leakage Current<1mA/240VAC
  
PROTECTION 
Over Load105%~150%
Protection type: Shut down o/p voltage, recovers automatically after fault condition is removed
Over Voltage115%~135%
Protection type: hiccup mode, auto-recovery
  
ENVIRONMENT 
Working Temp., Humidity-10ºC~+60ºC; 20%~90%RH
Storage Temp., Humidity-20ºC~+85ºC; 10%~95%RH
Temp. Coefficient±0.03%/ºC(0~50ºC)
Vibration10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes
  
SAFETY 
Withstand VoltageI/P-O/P: 1.5KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC
Isolation ResistanceI/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
  
STANDARD 
Safety StandardDesign refer to UL1012, UL60950,EN60950
EMC StandardDesign refer to EN55022(CLSPR22),EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024
  
OTHERS 
Dimension159*97*38mm(L*W*H)
Weight0.54Kg
Packing24pcs/13.8Kg/0.75CUFT
  
NOTE 
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12"twisted pair-wire terminated with a 0.1μ &47μparallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a finalequipment. The final equipment must be re-confirmed that it still meets EMCdirectives.






Scroll to Top