Description
Product Description
LPCB certified addressable fire alarm control panelIntroductionThe purpose of the AW-FP300Fire Alarm Control Panel (FACP) is to monitor input signals, give indications and possibly activate outputs as programmed. It is designed to comply with EN 54-2 with qualities of simple installation, operation and easy maintenance.
The AW-FP300panel is an addressable fire detection panel with 1 loop of 324 addressable points and expansion capabilities.It is compatible with other peripherals made by ASENWARE with its own protocol.
FeaturesThe AW-FP300 single loop 32 zone fire alarm control panel offers the following features:
1. Up to 324 addresses on one loop
2. An easy to read, 4.3'' color screen LCD with a resolution of 480×272
3. Zone indication and control panel(ZCP) for 32 zones gives a quick indication of the location of an alarm
4. Record capacity of 1000 historical events for each of historical fire, historical fault and historical operation
5. An independently programmable conventional sounder circuit output
6. Integral power supply and battery
7. Integral printer
8. Flexible and intuitive cause and effect programming on front panel
9. Zone test, point test and module start/stop testing facilitate the commissioning
10. U-disk interface makes the load and save of configuration or historical data convenient for system commissioning and maintenance
11. Hierarchy management with three access levels
12. Anti-tamper protection by a key lock
13. CAN bus for interconnection of up to 20 FACPs and RS485 for connection with up to 30 fire indicating panels per FACP
Parameters Power supply |
Mains supply | 230VAC (-15%, +10%). 47 ~ 63Hz. Max current 0.8A |
Mains fuse | T3.15AL250V |
Operating voltage | 18.5 ~ 30VDC |
Recommended mains cable | Screened or standard/black mains cable, cable size 0.75mm2 |
Power rating | Imax.a=1.2A; Imax.b=2.6A; Imin=0.65A |
Max. charging current | 1.2A |
Max. battery supply current | 4A (when the Mains is disconnected) |
Battery capacity, type and recommended model | Max. capacity 2×12V/17Ah; Min. capacity 2×12V/12Ah VRLA. PS-12170 for 17Ah (Power-sonic), PS12120 for 12Ah (Power-sonic) |
Max. internal resistance of battery | 1.5Ω |
Battery fuse | F8AL250V |
Recommended battery cable | 14AWG |
Quiescent current (full loaded) | < 0.4A |
Outputs |
S.C. Out (+, -) | Output voltage | 18.5 ~ 30VDC |
Max. output current | 0.5A |
Fuse rating | F1AL250V |
End of line resistor | 4K7 |
Recommended type of cable | Plain unscreened cable, 1.5mm2 |
Cable diameter | 1mm2 ~2mm2 |
Transmission distance | ≤1500m |
Max. number of sounders @50mA | 20 |
F.P.E. Out (+, -) F.A. Out (+, -) | Output voltage | 18.5 ~ 30VDC |
Max. output current | 0.5A |
Fuse rating | F1AL250V |
End of line resistor | 4K7 |
Recommended type of cable | Plain unscreened cable, 1.5mm2 |
Cable diameter | 1mm2 ~2mm2 |
Transmission distance | ≤1500m |
Fault Out (NC, COM, NO) | Contact capacity | 30VDC@2A, [email protected] |
Recommended type of cable | Plain unscreened cable, 1.5mm2 |
Cable diameter | 1mm2 ~ 2mm2 |
24VK (+, -) | Output voltage | 18.5 ~ 30VDC |
Max. output current | 0.6A |
Fuse rating | F1AL250V |
Recommended type of cable | Plain unscreened cable, 1.5mm2 |
Cable diameter | 1mm2 ~2mm2 |
Input |
Class change (+, -) | Input mode | Passive |
Cable resistance | ≤500Ω |
Recommended type of cable | Plain unscreened cable, 1.5mm2 |
Cable diameter | 1mm2 ~2mm2 |
Loop |
Loop Out (+, -) Loop In (+, -) | Output voltage | 16.5 ~ 30VDC, pulse |
Output current | 0 ~0.3A |
Loop type | Class A |
Recommended type of cable | Screened or unscreened twisted-pair, 1.5mm2 |
Transmission distance | ≤1000m |
Cable diameter | 1mm2 ~2mm2 |
Network communication |
RS-485 | Max. number of FIPs | 30 |
Transmission rate | 9600 bps |
Recommended type of cable | Screened or unscreened twisted-pair, 1mm2 |
Transmission distance | ≤1000m |
Cable diameter | 1mm2 ~5mm2 |
CAN | Max. number of panels | 20 |
Transmission rate | Optional: 10K, 20K, 50K and 100K bps |
Recommended type of cable | Screened or unscreened twisted-pair, 1mm2 |
Transmission distance | ≤1000m |
Cable diameter | 1mm2 ~5mm2 |
Physical dimensions |
Approx. Dimensions of the panel (W×H×D) | 430×560×170mm |
Approx. weight (without battery) | 14kg |
Operating conditions |
Temperature range: 0°C~45°C; Max relative humidity: 95% (40°C ±2°C, no condensation) |
Company InformationAsenware, is the fire alarm system and fire suppression system manufacturer and whole fire safety solution provider since 2005
Driven by a commitment to sound operations, ongoing innovation, and open collaboration, we have established a competitive fire safety products line include addressable fire alarm system, conventional fire alarm system, central monitoring emergency light system, fire telephone and emergency audio systemm, fire pump, fire hose and gas suppression system.
Our fire safety products, solutions and services are used in over 100 countries.
With over 200 employees work in United Kingdom-Marketing center, China-R&D and Supply Chain center and Bangladesh-Manufacture center, Asenware is committed to design and manufacturer the best fire safety products to reduce the risk of fire, and support the world to be more safe and more comfortable.
Product rangeAddressable fire alarm system
Conventional fire alarm system (2166 series)
FM200 gas suppression system (2159 series)
Fire pump
Fire hose/ hose reel and cabinet
ABC powder/ CO2 fire extinguisher
Emergency light system
CertificatesService1) OEM & ODM service: YES
2) Technical support and After-sale service: YES
3) Warranty: 1 YEAR
4) Delivery Time: 3 - 5 days after payment received
5) Shipping: delivery by air, ship or DHL, FEDX etc. Express for your order
Contact