Sf6 Analyzer Multi Gas Detector Sf6 Gas Sensor

Min.Order: 1
Product origin: Chongqing, China
Infringement complaint: complaintComplaint
US$ 3000 ~ 8000

Description
Sf6 Analyzer Multi Gas Detector Sf6 Gas Sensor
 
Product Description


Sf6 Analyzer Multi Gas Detector Sf6 Gas Sensor integrates SF6 micro- water detector, SF6 purity tester, and SF6 decomposition analyzer as one. One time field measurement can complete the three detections, greatly save the gas in the device, which can save 2/3 of gas usage, while reduce the user's workload and improve work efficiency. 
 

Product Features

 

1. Fast and save gas: after startup into the measuring state, the measuring time of dew point is about 5min; the measuring time of SF6 purity and SF6 decomposer is about 2min; 

2. Self-lock joint: use the self-lock joint imported from German, safe and reliable, without gas leakage. 

3. Data storage: high capacity, can store 200 groups test results at the most. 

4. Curve function: Large-screen curve display the process of dewpoint measurement 

5. Clearly display: the dew point, micro-water (ppm), SF6 purity, SO2, H2S, CO and HF content, and temperature, humidity, time and date, etc, are displayed by LCD. 

6. Built-in power supply: built-in 4Ah chargeable lithium battery, filled one time, can work for 10 hours. 

 

Product Parameters

 

PurityMeasurement range: 0% to 100%
Measurement accuracy: ±0.5%
 Repeatability: ±0.2% 
 Response time: 90% 15s 
 H2S  Measurement range: 0~200uL/L 
 Minimum detectable amount: ≤0.1ppm 
 Accuracy: H2S≤10uL/L, ±1uL/L; H2S>10uL/L, ±10% 
 Resolution: H2S≤10uL/L, ±0.5uL/L; H2S>10uL/L, ±5% 
 Repeatability: H2S≤10uL/L, ±0.5uL/L; H2S>10uL/L, ±5% 
 Response time: ≤5min 
 SO2  Measurement range: 0~200 uL/L 
 Minimum detectable amount: ≤0.1ppm 
 Accuracy: SO2≤10uL/L, ±1uL/L; SO2>10uL/L, ±10% 
 Resolution: SO2≤10uL/L, ±0.5uL/L; SO2>10uL/L, ±5% 
 Repeatability: SO2≤10uL/L, ±0.5uL/L; SO2>10uL/L, ±5% 
 Response time: ≤5min 
 CO  Measurement range: 0~1000 uL/L 
 Minimum detectable amount: ≤1ppm 
 Accuracy: CO≤50uL/L, ±4uL/L; CO>50uL/L, ±8% 
 Resolution: CO≤50uL/L, ±5uL/L; CO>50uL/L, ±4% 
 Repeatability: CO≤50uL/L, ±2uL/L; CO>50uL/L, ±4% 
 Correspondence time: ≤5min 
 HF(Optional)  Measurement range: 0~10 uL/L 
 Minimum detectable amount: ≤0.1ppm 
 Accuracy: HF≤1uL/L, ±0.1uL/L; HF>1uL/L, ±10% 
 Resolution: HF≤1uL/L, ±0.05uL/L; HF>1uL/L, ±5% 
 Repeatability: HF≤1uL/L, ±0.05uL/L; HF>1uL/L, ±5% 
 Response time: ≤5min 
 Ambient temperature   -40ºC~+60ºC 
 Withstand pressure   Instrument pipeline withstand pressure not more than 1MPa 
 Ambient humidity   0~100% RH 
 Power supply AC   100~240V 50/60Hz 
 Built-in rechargeable battery 
 Battery performance   Charging time: 10 hours; use time 12 hours or more 
 Operating temperature   -30ºC~+50ºC 
 Dimensions   280×190×300 mm 
 Weight   7.6 kg 
 