Portable Three-Phase Intelligent Phase Volt-Ammeter Digital Phase Va Meter AC Voltage Range 0 to 600V Current 0 to 30A Three Clamps Phase Meter

Min.Order: 1
Product origin: Wuhan, Hubei, China
Infringement complaint: complaintComplaint
US$ 199 ~ 799

Description
General Information:
EP8410B The three-phase intelligent phase voltammeter is a multifunctional intelligent instrument designed for on-site testing. It consists of a host, current clamps (3), and test lines (4). The host uses a 3.5-inch true color LCD screen, graphical menu interface display, vector diagram instructions. The design of the small clamp head of the current clamp is easy to operate, and it is very suitable for places with dense wiring. The instrument can measure three-phase AC voltage, current, phase between voltages, phase between currents, phase between voltage and current, frequency, phase sequence, active power, reactive power, apparent power, without opening the circuit under test. Power factor, current vector sum, identify the transformer wiring group, inductive, capacitive circuit, test the secondary circuit and bus differential protection system, read out the phase relationship between the CTs of the differential protection groups, check the correct connection of the meter Otherwise, the maintenance of line equipment, etc., provides a safe, accurate and convenient smart instrument for the electricity inspectors. It is suitable for electric power, petrochemical industry, metallurgy, railway, meteorology, industrial and mining enterprises, scientific research institutions, metrology departments, etc. Especially suitable for electric energy billing system and relay protection system.


Technical Specifications:
1. Baseline conditions and working conditions
 
ItemBaseline conditionsWorking conditionsRemark
Ambient temperature23ºC±1ºC-10ºC~40ºC/
Ambient humidity40%~60%<80%/
Signal waveformSine waveSine waveβ=0.01
Signal frequency50HZ±1Hz45Hz~65Hz/
Working voltage7.4V±0.5V7.4V±1V/
Current amplitude when measuring phase frequency phase sequence1A±0.1A1mA~30ACheck general specifications for details
Voltage amplitude when measuring phase frequency phase sequence100V±10V1V~600V/
Current amplitude when measuring power factor1A±0.1A10mA~30A/
Voltage amplitude when measuring power factor100V±10V10V~600V/
External electric field, magnetic fieldShould be avoided
The position of the test wire under testThe tested wire is at the approximate geometric center of the clamps

2. General specifications
FunctionSimultaneously test the current, voltage, phase, frequency, phase sequence, active power, reactive power, apparent power, power factor, current vector sum in the three-phase 380V / 220V power system to determine the transformer wiring group, inductive, capacitive Circuit, test the secondary circuit and bus differential protection system, read out the phase relationship between the CTs of the differential protection groups, check the correctness of the wiring of the watt-hour meter, repair the line equipment, etc.
 PowerDC 7.4V large-capacity rechargeable lithium battery, USB charging interface, continuous working for about 10 hours when fully charged.
Rated currentAbout 180mA Max
Display mode3.5 inch true color LCD display
Meter size LWH:196mm×92mm×54mm
Clamp sizeφ7.5mm×13mm
Sampling rateAbout 3 times / sec
Measuring rangeAC voltage: 0.00V ~ 600V
AC current: 0.0mA ~ 30A
Phase:0.0°~360.0°
Frequency:45.00Hz~65.00Hz
Active power:0.0W~12kW
Reactive power:0.0VAR~12kVAR
Apparent power:0.0VA~12kVA
Power factor:-1~+1
Current vector sum:0mA~60A
ResolutionVoltage:AC 0.01V
Current:AC 0.1mA
Phase:0.1°
Frequency:0.01Hz
Active power:0.1W
Reactive power:0.1VAR
Apparent power:0.1VA
Power factor:0.001
Current vector sum:1mA
Precision
(Under baseline conditions)
Voltage:±(0.5% measuring range)
Current:±(0.5% measuring range)
Phase: ± 1 ° (Phase error under working conditions: ± 3 ° from 10mA to 30A; ± 5 ° below 10mA. When the current value is less than 5mA, in order to ensure that the current is accurately measured on the current phase, do not perform voltage measurement In the phase test of voltage to current, in order to ensure the accuracy of the measurement, the voltage needs to be not less than 5V and the current is not less than 5mA)
Active power: ± (1.0% of range)
Reactive power: ± (1.0% of range)
Apparent power: ± (1.0% of range)
Frequency: ± (1.0% of range)
Power factor: ± 0.03
Phase sequenceNormal phase: U1, U2, U3 or I1, I2, I3 cursor flashes sequentially from left to right
Reverse phase: U1, U2, U3 or I1, I2, I3 cursor flashes sequentially from right to left
Detection rateAbout 2 seconds / time
Data retentionPress HOLD key to keep the data during the test, the "HD" symbol is displayed
Data storage99 groups
Charging interfaceUSB charging interface
Automatic shut-downAbout 15 minutes after starting up, the meter will automatically shut down to reduce battery consumption
Backlight functionYes, the backlight brightness can be adjusted
Voltage detectionWhen the battery voltage is lower than 6.5V, the battery voltage low symbol is displayed, reminding the battery to charge, and automatically shut down within 10S.
WeightHost: 350g (with battery)
Current clamp:170g×3
Total weight:about 1.35kg
Test lead length1.5m
Current clamp wire length2m
Working temperature and humidity-10ºC~40ºC, below 80%Rh
Storage temperature and humidity-10ºC~60ºC, below 70%Rh
Input resistanceThe input impedance of the test voltage is: 1MΩ
Withstand voltageThe sine wave AC voltage of 1000V / 50Hz between the instrument circuit and the shell lasted 1 minute
Insulation≥100MΩ between instrument circuit and sheath shell
Suitable for safety regulationsIEC61010-1 CAT III 600V, IEC61010-031, IEC61326, pollution degree 2

More details on Three Clamps Intelligent Phase Volt-Ammeter please contact EP Hipot Electric, we have professional tech team to design correctly designed products and systems.







Product Tag:
Related categories:
Scroll to Top