NO. | Item | Contents |
1.1 | Motor construction | Inne rotor BLDC motor |
1.2 | Number of phases | 3-phases 3 |
1.3 | Number of magnet poles | 4-poles 4 |
1.4 | Rectifying method | Electronic commutator device |
NO | Item | Specification | Condition / Remark / |
2.1 | Rated voltage | AC220V | Main power supply |
2.2 | Rated load | 400W max | 4000200RPM max |
2.3 | Rotation direction | CW/CCW | By controller. . |
2.5 | Voltage range for use | 180V-240V | |
2.6 | Power range for use | 0-520W(max) | Power in |
2.7 | Operating conditions | -20ºC~50ºC 15%~90%RH | ordinary humidity no condensation of moisture |
2.8 | Storage conditions | -20ºC~70ºC 15%~75%RH | ordinary humidity no condensation of moisture/ |
NO. | Item | Measuring condition | Specification |
5.1 | Standby power | At Rated voltage and no load | ≤ 20W |
5.2 | Rated Load | At Rated voltage and rated load | |
5.3 | Rated power | 400W | |
5.4 | Rated speed | 4000rpm200 | |
5.5 | Terminal resistance | Measured between terminal | 8±8%Ω |
5.6 | Insulation resistance | At DC 500V, measured between housing case and terminal. 500V , | ≥ 20M |
5.7 | Insulation voltage | AC1800V between lead wire and motor case during one sec. AC1800V | Leakage current ≤ 2mA |
NO. | Item | Test condition | Requirements |
6.1 | Life test | 1.Condition of temperature: Normal temperature and humidity 2.Test state: Fix the motor in a test jig (keep the body of the motor Shaft Vertical) () 3. Voltage: DC24V 4. Load: 200 5.Test mode: Continuous operating with rated load 10000 hours10000 | After the test, the motor should conform to the requirements of the items 7.1 to 7.4. , 7.1~7.4 |
6.2 | Low temperature storage | Temperature:-20ºC±2ºC Time: 72h | 2 hours after the test, in the condition of the normal temperature and normal humidity, the motor should conform to the requirements of the items 8.1 and 8.2. ,2, 7.1,7.2 |
6.3 | High temperature exposure | Temperature :+65ºC±2ºC Time: 72h | |
6.4 | Humidity test | Temperature:40ºC±2ºC Humidity: 90%~95% RH Time: 72h | |
6.5 | Thermal Shock test | Temperature :-30ºC~ 70ºC Time: 2h Circle cycle:10times | 4 hours exposured in the normal temperature and humidity after thetest, the motor should conform to the requirements of the items 7.1 and 7.2. ,4 , 7.1,7.2 |
(5)Q: What advantage do you have?
A: For motors, we have quality guarantee, if there is probelm motor after inspection in customer house,we will replace .
For service, we offer 24 hours technical support and barrier-free communication with excellent service people.
Technical service: Except offer actual motor products,we can also offer motor technical supporting seperately to our customer.Our engineers are represent the most advanced techonogy.