PowerSupply | Rated voltage, Frequency | One-phase/Three-phase AC 220V 50/60Hz | |
Voltage Range | 220V: 170~240V;380V:330V-440V | ||
Output | Voltage Range | 220V: 0~220V;380V:0-380V | |
Frequency Range | 0.10~400.00Hz | ||
Control method | V/F control, Space vector control. | ||
Indication | Operating status/Alarm definition/interactive guidance: eg , frequency setting, the output frequency/ current, DC bus voltage, the temperature and so on. | ||
Control SpeciAlations | Output Frequency Range | 0.10Hz~400.00Hz | |
Frequency Setting Resolution | Digital input: 0.01Hz, analog input: 0.1% of maximum output frequency | ||
Output FrequencyAccuracy | 0.01Hz | ||
V/F Control | Setting V/F curve to satisfy various load requirements. | ||
Torque Control | Auto increase: auto raise torque by loadingCondition; Manual increase: enable to set0.0~20.0% of raising torque. | ||
MultifunctionalInput Terminal | Four multi-function input terminals, realizing functions including fifteen section speed control, Program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions | ||
Multifunctional Output Terminal | 1 multi-function output terminals for displaying of running, zerospeed, counter, external abnormity, program operation and other Information and warnings. | ||
Acceleration/ deceleration Time Setting | 0~999.9s acceleration/deceleration time can be set individually. | ||
Other functions | PID Control | Built-in PID control | |
RS485 | Standard RS485 communication function(MODBUS) | ||
Frequency Setting | Analog input: 0 to 10 V, 4 to 20mA can be selected; | ||
Digital input:Input using the setting dial of theoperation panel or RS485 or UP/DOWN. | |||
Note:AVI terminals can be used to select an analog voltage input(0-10v) and analog current input(4-20mA) through the switch J2. | |||
Note: AVI terminals can be used to select an | |||
Analog voltage input (AV) and analog current | |||
Input(AI) through the switch J2. | |||
Multi-speed | Four multifunction input terminals, 15 section speed can be set | ||
Automatic voltage regulation | Automatic voltage regulation function can be selected | ||
Counter | Built-in 2 group of counters |
Model | Power Output | Capacity | Current Output | Load Capacity | Motor Equipped |
(KW) | (KWA) | (A) | (60s)(A) | (KW) | |
S800-2S0.4GE | 0.4 | 1 | 2.5 | 3.75 | 0.4 |
S800-2S.75GE | 0.75 | 2 | 5 | 7.5 | 0.75 |
S800-2S1.5GE | 1.5 | 2.8 | 7 | 10.5 | 1.5 |
S800-2S2.2GE | 2.2 | 4.2 | 11.0 | 16.5 | 2.2 |
Model | Power | Capacity | Current | Load | Motor |
Output | (KVA) | Output | Capacity | Equipped | |
(KW) | (A) | (60s)(A) | (KW) | ||
S800-4T0.75GE | 0.75 | 2.2 | 2.7 | 4.05 | 0.75 |
S800-4T1.5GE | 1.5 | 3.2 | 4.0 | 6.0 | 1.5 |
S800-4T2.2GE | 2.2 | 4.0 | 5.0 | 7.5 | 2.2 |