JFAD Energy feedback charger is a new generation power supply product developed by our company and proved by customers. The energy feedback tester is based on the advantages of our original tester, and absorbs the advanced technologyof similar products in the world. It is developed by ourselves according to market research and customer demand.
The equipment supports battery standard charge and discharge test, cyclic charge and discharge test, capacity test, charge and discharge characteristic test, charge and discharge retention test, charge and discharge efficiency test, over-charge and over-discharge test, power and energy measurement test, energy efficiency test. The equipment can realize various complex process logic, has strong data analysis ability, and supports docking with third-party equipment.
System parameter | ||
Model | JFAD-5V10A256L | |
Channels | 256 | |
Control Mode | Every channel is independent control | |
Range and precision | ||
Current | Output Range | 0-10A |
Control Precision | ±0.05%RD±0.05%FS | |
Test Precision | ±0.05%RD±0.05%FS | |
Voltage | Output Range | Charge:0-5V Discharge:1.5-5V |
Control Precision | ±0.05%RD±0.05%FS | |
Test Precision | ±0.05%RD±0.05%FS | |
Work Mode | ||
Charge Mode | CC charge,CV charge | |
End Charge Condition | Voltage,current,time,capacity,single voltage | |
Discharge Mode | CC discharge | |
End Discharge Condition | Voltage,time,capacity,single voltage | |
Hardware Control Technology | ||
Adopt international advanced control technology, the two-way flow of energy with high quality can be realized in the testing process, which has the characteristics of high control accuracy, fast response and conversion time, and small ripple, and meets the requirements of high-standard testing. | ||
Power Saving and Power Grid | ||
Energy Feedback | Rectification efficiency:80%,Inverter efficiency 75%(Full load)) | |
Grid-side power factor | ≥0.99(Full load) | |
Equipment characteristics | ||
Average normal running time | >5000h | |
Equipment noise | 75dB | |
Long-term continuous operation and normal operation under rated current condition | ||
Program | ||
Recycles | Max 3 cycles | |
Steps | 250steps | |
Recycle Range | No limit | |
Record Mode | Time interval, current interval, voltage interval. Every step can set different record mode. | |
Record | ||
Min. Record Frequency | 0.1s | |
Data Format | Binary | |
Output Record Format | Excel,text file | |
Records | Single file10M | |
Data Analysis Speed | 1M/s | |
Communication | ||
Communication Mode | Internet/UDP | |
Power | ||
Input Power Voltage | 3Phase 415V±5%/50Hz | |
Isolation Mode | Transformer | |
Power | ||
Input Power | 16KW | |
Others | ||
Working Ambient Temp. | 0ºC-40ºC | |
Working Ambient Humidity | 10%-75%humidity |