Description
Portable 810nm Diodes Laser Hair Removal Machine DL811 Theory of the diode laser hair remove machine:
Diode laser hair removal technology is based on the selective dynamics of light and heat.
The laser goes through the skin surface to reach the root of hair follicles, light can be absorbed
and converted into heat damaged hair follicle tissue. So that hair loss regeneration without
injury surrounding tissue. With slight pain, this is the most the safest, quick, and permanent
technique for hair removal now.
Diode laser equipment adopts 810nm, which is particularly effective to hair follicles
melanocytes without any injury of surrounding tissue. The laser light can be absorbed by
melanin in the hair shaft and hair follicles, and then converted into heat, thus increasing the
hair follicle temperature. When the temperature raises high enough, the hair follicle structure
will be damaged irreversibly, and then disappeared after a period of natural physiological
The details display of the machine:Application Permenent hair removal, better than IPL and E-light; Remove hair on different part of body effectively. Such as armpit hair , beard, lip hair, hair line, bikini line, body hair and other unwanted hair.
Also Relieve symptoms of speckle, telangiectasis, deep color naevus, spider lines, red birthmark and so on.
Features1. With Sapphire Crystal on the treatment head that can be used forever without replacement;
2. Powerful semiconductor cooling, air cooling and water cooling can ensure longer working time.
3. Water cycle& water temperature checking system and powerful abstractor extend the service life and safety for the machine;
4. Short treatment time and quick recovery have little effect on patients' daily work.
5. Advanced flash computer calculater: xenon lamp computer calculater system always show how many flashes you have used.
6. Easier installation: plug-and-play connectors.
7. Minimum energy loss: ceramic silver-gilt lumen refelcts diffuse light onto laser rod to produce stronger power.
8. Medical CE approval, ISO9001:2008.
ParameterLaser Type: High Quality 810nm Semiconductor laser beam soure
Wave Length: 810nm
Output: 810nm Treatment of handle out direct output mode (hand gun type)
Mode: Single Pulse and Continuous pulse
Frequency: 1~10Hz
Pulse Width: 10-200 ms
Spot Size: 10x12 mm²
Energy Density: 0-150J/cm2
Electrical Requirement: AC 220V±10% 50Hz; AC 110V±10% 60Hz
Cooling System: water cooling + wind cooling + Semiconductor
Temperature: 0-40ºC
Input Power: 1200W
Fuse :Max10A
Gross weight: 30KGS
Machine size: 45cmx49cm*35cm
pacakge size:65cmx258cmx46cm
Cautions after treatment:
1: After finished treatment, the treatment area will feel slightly scorching hot and skin around hair follicles appears erythema, which is normal phenomenon, do ice compress to partial skin for 10-15 minutes if needed;
2: the residual hair on treatment area can pull out in 24 hours or automatically fall off in several days;
3: The current day of treatment, use low temperature water to wash and use liquid skin care products;
4: After treatment, pay attention to protecting moisture and sunscreen;
Cautions before and after therapy:
1: One month before treatment, pay attention to the sunscreen;
2: Two weeks before treatment, the treatment area does not remove hair with plucking out, with cream or electrolysis ;
3: Two days before and after treatment, to avoid chemical or mechanical stimulation;
4: Two weeks before and after treatment, to disable the filling or other injection, etc the kind of interventional therapy;
Therapy periods:
Underarm, Face: One Therapy interval---4-6 weeks;
Arms and legs, body: One Therapy Interval----4-6 weeks;
Treatment Period: 3-5 times;
Contraindications:
The following symptoms are forbidden to use:
The pregnant
Recently (within 1-3 months) accepted the sun exposure or sun bath
The patient with open wound
The patient with infected wounds
The patient suffering from skin disease
The patient with epilepsy
Attentions:
1: First check the host, accessories, power supply wire is broken or not before use;
2: connect correct voltage (220V to 220V, 110V to 110V), can not get through wrong voltage.
3 Start system, in addition to television, refrigerator, Do not turn on electrical power device at the same time;
4 Before therapy, please take hearing aid, electronic wristwatch, magnetic card, mobile phone or other things off first, pay attention to child's care to avoid touching;
5 During the therapy, drink more water based on your physical;
6 In case of happening special circumstances or accident, please immediately stop using and consult professionals;
7 Patients with above mentioned medical electrical device can not use this system at the same time;
8 Above mentioned patients should be agreed by professionals before using this device;
9 Please immediately turn on power supply, stop using if following abnormal situation happened:
9A water or other things into host;
9B: The sound of system to be unusual;
9C Abnormal smell or smoke;
9D: Any accessories broken;
9E: Natural disaster, earthquake, and the sudden thunder;
10: When the treatment is finished, please cut off the power supply, be sure to unplug the power plug from the power socket;
11: Transportation and storage conditions: the transport process should be to prevent sun and rain, packaged equipment should be stored in relative humidity of not more than 80%, no corrosive gas and ventilated room;