F15 Medical Multi-Parameter Portable Ambulance Hospital ICU Patient Monitor


patient monitor Features:
15' color TFT LCD screen supports display max. 11 waveforms 
Personated voice reminding alarm; Visual On-display and integrated alarm light 
Display mode: Standard, Large Font, NIBP Trend, Trend Table, Full lead ECG, Oxy CRG.
Drug calculation and titration table
Real time ST segment analysis, pace maker detection and Arrhythmia analysis, 
Extended advance function: IBP, IOC, EtCO2, Multi-gas/O2
Suitable for monitoring adult, pediatric and neonatal patient. 
Supporting storage of 720 hours patient data, 1000 NIBP records and 500 alarm event.
Internal lead-acid battery 
Multi-language: Chinese, English, Spanish, Portuguese, Russian, French, German, Czech, 
Denish, Dutch, Finland, Italian, Porlish, Turkish
Standard Configuration:
Anti-glare big screen, rechargeable lead-acid battery, 3/5-Lead ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional Configuration:
2IBP, Nellcor SpO2, Depth of Anesthesia Monitoring Module, EtCO2 (Main-stream/Side-stream/ Micro-stream CO2), Multi-Gas/ O2, Pitch Tone
VGA, Thermal printer (50 mm)
Roller stand with locking castors and intergrades castors
Pediatric / neonatal accessories: reusable NIBP cuff & SpO2 probe; disposable NIBP cuff & SpO2 probe
Physical Specifications
Dimension and weightDimension330mm(W)*260mm(H)*140mm(D)
Weightstandard configuration: 4 kg
Operation environmentPower requirementsAC 90-300V, 50/60HZ, 60W
Power90VA
Temperature0-40ºC
Humidity0-93% non-condensing
SafetyMeet the requirements of IEC60601 series
Patient rangeAdult, neonate and pediatric patients
Performance Specification
Display                           15' color TFT LCD screen, support external VGA(option). rolling and refreshing waveform display
Display modeStandard, large font, NIBP trend, trend table, full lead ECG, Oxy CRG.
Interface
 
 

 
Parameter cable interface
AC power input socket
Network interface
External VGA interface for connection of alternate display
Battery1 internal rechargeable lead-acid battery, 2.0Ah 12V
Alarm indicatorVisual on-display and integrated alarm light
Audible alarm and personated voice reminding alarm
Data storage
 
720 hours monitoring data
10000NIBP records storage 
500 alarm event.   
Printer
 

 
Built-in 50mm thermal printer (option), 
3 traces, print speed 12.5mm/s & 25mm/s & 50mm/s  
print width:50mm
Net workingSupport connection to central monitoring station through LAN (TCP/IP) or wireless connection 
ECG
Leads type3/5-lead : I, II, III, aVR, aVL, aVF, V
Sweep speed12.5mm/s, 25mm/s,50mm/s
Gain selection×0.25,×0.5, ×1, ×2
ECG waveform3 channels
Operation modeDiagnostic, monitor, surgery
Heart rate range15 -350bpm
Accuracy1bpm or ±1% whichever is great
Alarm rangeAudible and visual alarm, adjustable
ST/ arrhythmiaReal time S-T segment detection, pace detection and arrhythmia analysis
ProtectionAgainst electrosurgical interference and defibrillation
Respiration (RESP)
MethodThoracic impedance
Operation modeAuto/manual
Measurement rangeAdult: 0-120BrPM; neonatal /pediatric: 0-150BrPM
Apnea alarmYes
AlarmYes, audible and visual alarm ,alarm events recallable
NIBP
MethodAutomatic oscillometric
Operation modeManual/Automatic/STAT
Auto measure timeAdjustable
Measurement unitmmHg / kPa  selectable
Test interval1-480 minutes
Measurement range
 

 
Adult: 0-300 mmHg ;   
Child: 0-240 mmHg ;    
Infant: 0-150 mmHg
Over-pressure protectionDouble safety protection
Accuracy of blood pressure     measurementThe mean error shall be less than±5mmHg
the standard deviation shall be less than 8mmHG
Resolution1 mmHg
SpO2
Measurement range0%-100%
Resolution1%
Accuracy±2% (70-100%, adult/pediatric, non-motion )
±3% (70-100%, neonate, non-motion )
±3% (70-100%, adult/pediatric/neonate, motion )
0-69% unspecified
Alarm range1-100%
Pulse rate                         Pulse range:0-350bpm
Accuracy:±3bpm(non-motion)
±5bpm(motion )
Temperature (TEMP)
TEMP range0-50ºC
Resolution0.1 ºC
Accuracy±0.1ºC  (excluding the sensor)
ChannelDual-channel. provide T1;T2; T
IBP
Measurement range-50-360mmHg
Channel2 channels
Pressure transducerSensitive :5u V/V mmHg
Impedance range :300-3000 Ω
Pressure namesART,PA,CVP,RAP,LAP,ICP,P1,P2
Alarm range-10-300 mmHg
PR from IBPRange & Accuracy:25-200bpm  ±1bpm or ±1bpm which is greater
201-350bpm ±2%
Resolution :1bpm
Depth of Anesthesia (BIS)
EEG sensitivity+/- 475μV
Noise< 2uVp-p (1-150 Hz)
CMRR> 100 dB
Input impedance> 50mohm
Sample rate1024 samples/s, 16 bits
Index and display update0-100, filter 1-47 Hz, 1 sec. display update
EEG waveform± 500 µV scaleable, filter 1-30 Hz, 3 sec. window length.                              
ESR0-100%
EMG 0-100 arbitrary unitCurve and bar
Index trend5 min and 60 min
Digital outputWireless BT interface (RFCOMM). 10 meters range
AlarmsIoC high and low user selectable limits
Artifact rejectionAutomatic: user can disable.
Sensor impedance range0 - 14kohm
EtCO2 (Main-stream / Side-stream / Micro-stream CO2)
Measurement range0-150mmHg
Accuracy±2mmHg(0-40mmHg)
±5% of reading(41-76mmHg)
±10% of reading (77-99mmHg)
Resolution1mmHg
Sampling rate70m1/min 100m1/min
Sampling rate accuracy0.15 or 15m1/min
Start-up time
 
30 Sec. the module enters the warming up status after the start up.
1 minute later, it enters the ready-to-measure status.
Respiration rate3-150 rpm
Respiration rate accuracy±2BrPM (0-70BrPM)
±5BrPM (>70BrPM)
Response time
 
 
 
 

 
When measured with a neonatal water trap and a 2.5 m-long neonatal sampling line:
< 3s @ 100 ml/min 
<4 s @ 70 ml/min
When measured with an adult water trap and a 2.5 m-long adult sampling line:
<5.5 s @ 100 ml/min 
<7 s @ 70 ml/min
Delay time
 
 
 
 

 
When measured with a neonatal water trap and a 2.5m-long neonatal sampling line:
<3 s @ 100 ml/min 
<3.5 s @ 70 ml/min
When measured with an adult water trap and a 2.5m-long adult sampling line:
<5 s @ 100 ml/min
<6.5 s @ 70 ml/min
Multi-Gas/O2
MethodInfrared absorption
Gas sortsCO2, N2   CO2, N2O, Des, Iso, Enf, Sev, Hal, O2, 
(Optional paramagnetic sensor)
Measurement range
 
 
 
 

 
CO2: 0~30%
N2O : 0~105%
O2,  :0~105%
Enf, Iso, Hal: 0~30%
Sev: 0~30%

Des:0~30%
Data outputFi and ET values
Respiration rate
 
±1BrPM(2~60BrPM)
61~100BrPM (unspecified)
Other
 
Up to 4 waveforms displayed
Agent mixture detection
MAC value displayed 