Model | XGQ -100F | XGQ -80F | XGQ -50F | XGQ -25F | XGQ -15F |
rated capacity (dry loading) | 100 | 80 | 50 | 25 | 15 |
Drum D×L (inner size) | 1240×840 | 1150×800 | 990×660 | 810×520 | 650×460 |
CylinderD×L (inner size) | 1322×953 | 1216×918 | 1060×754 | 870×615 | 710×533 |
washing/distributing speed | 30/60 | 30/60 | 40/60 | 43/75 | 45/82 |
middle/high extracting speed | 325/650 | 360/700 | 375/750 | 430/810 | 440/920 |
work cycle | 45 | 45 | 45 | 45 | 45 |
motor power (frequency converting and speed changing) | 7.5 | 6.5 | 4 | 3 | 1.5 |
power of electric heating pipe kw | | | 45 | 22.5 | 12 |
steam pipe(DN) mm | 25 | 25 | 20 | 20 | 15 |
cool/hot water pipe(DN) (DN)mm | 40 | 40 | 25 | 25 | 20 |
water consumption of cycle kg | 1800 | 1200 | 750 | 400 | 300 |
steam consumption of cycle kg | 50 | 45 | 30 | 20 | 8 |
power consumption of cycle (frequency converting and speed changing) | 1.8 | 1.6 | 1(steam heating) 7(electricheating) | 0.8(steamheating) 5(electricheating) | 0.4(steam heating) 3.5(electricheating) |
tap water pressure mpa | 0.2-0.3 | 0.2-0.3 | 0.2-0.4 | 0.2-0.4 | 0.2-0.4 |
mpa steam pressure | 0.4-0.6 | 0.4-0.6 | 0.4-0.6 | 0.4-0.6 | 0.4-0.6 |
work pressure of compressed air | 0.4-0.5 | 0.4-0.5 | 0.4-0.5 | 0.4-0.5 | 0.4-0.6 |
dimension (L×W×H) mm | 1920×1700×2020 | 1875×1600×1930 | 1440×1320×1700 | 1285×1150×1540 | 950×800×1300 |
machine weight | 2900 | 2700 | 1550 | 1100 | 420 |