Single-Phase Handheld Field Harmonic Analysis Calibrator

Min.Order: 1
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 510

Description
Harmonic analysis
Function description
1. Perform the 2nd ~ 51st harmonic analysis on the measured signal, and test the total harmonic distortion rate,
odd and even times and each harmonic content.(note: test the 2nd ~ 21st harmonics according to the national
standard)
2. Test and analyze three-phase voltage and current, respectively, show the harmonic content of each harmonic in
the form of corresponding light bar chart, and display the percentage of corresponding harmonic content
accordingly.
Press "3 harmonic" key to enter the "harmonic" state, and after entering the interface, the interface below displays
15PEC-HA Single-phase energy meter field calibrator -- User manual
voltage, current and sorting three options; select voltage and press "F2" key, choose current and press "F3", select
sorting and press "F5", show the each harmonic content of current or voltage according to the operation, and the
biggest harmonic on the scale line is full scale. If the harmonic is very small, only parts per ten thousand, such as
maximum 0.06%, the percentage value of the highest scale is 0.06%, and the subtle harmonic is amplified, clear at
a glance.
The instrument can test a total of 2nd ~ 51st harmonics, and show harmonic spectrum and give out the percentage
content of each harmonic. The 21st harmonic is used as an example in the following to calculate (the 51st harmonic
is calculated the same as the 21st harmonic)
Wherein:
Percentage content of each harmonic - refers to the percentage of the effective value of the 2nd ~ 21st harmonic
relative to the effective value of fundamental wave, defined as follows:
(of which i = 2, 3, 4 · · · · · · 21; Ui is the effective value of each harmonic, and U1 is the effective
value of fundamental wave.);
Harmonic order - refers to the multiples of fundamental wave frequency, relative to fundamental wave. If the
frequency of mains supply is 50Hz, the 2nd harmonic is 100Hz AC component, the 3rd harmonic is 150Hz AC
component and so on.
Channel indicator -- the harmonic state of the channel currently tested.(six channels are
respectively:);
16PEC-HA Single-phase energy meter field calibrator -- User manual
Odd order harmonic distortion rate - refers to the percentage of the total effective value of odd harmonics relative
to the effective value of fundamental wave, defined as follows:
In case of
Then, odd aberration rate
Even order distortion rate - refers to the percentage of the total effective value of even harmonics relative to the
effective value of fundamental wave, defined as follows:
In case of
Then, the even order distortion rate
Then, the total harmonic distortion
Total harmonic distortion--refers to the percentage of the total effective value of harmonics relative to the
effective value of fundamental wave, defined as follows:
In case of
Then, the total harmonic distortion
17PEC-HA Single-phase energy meter field calibrator -- User manual
The scale line - the biggest harmonic is full.
Harmonic pollution to power grid is becoming more and more serious, so the harm caused by harmonics can not
be ignored, mainly reflected in:
1. Greatly increasing the chance of resonance in power grid, thus causing the risk of accidents arisen from very
high overcurrent or overvoltage;
2. Increasing additional loss, and reducing the efficiency of power generation, transmission and power equipment
and the equipment utilization;
3. Increasing the losses to electrical equipment (rotary motors, capacitors, transformers, etc.), accelerating the
insulation aging, and thus shortening the service life;
4. Enabling the relay protection and automatic device, computer systems, and a lot of electrical equipment to run
abnormally;
5. Leading to the metering and measuring instruments (such as: energy meter) not to give correct instructions or
measurement;
6. Interfering with the communication system, lowering down the quality of signal transmission, disturbing the
normal transmission signal, and even damaging the communications equipment.
18

 

 
General
Power supplyAC 87~265V, 50~60Hz
Power consumptionAbout 10VA
Ambient temperature-20ºC--+40ºC (accuracyassured)
Relative humidity (not condensing)40%-90%
Dimension(D×W×H, mm)249×154×58
Weight1.5Kg
Warm-up time< 3 minutes
Battery endurance4hours
LCD color display5.7", 320×240 TFT
Communication portRS 232
Data storage8 mega bite
Safety
Declaration of conformityCE conformed
Operation reference
Measuring rangeAC 30~265V
Intrinsic errors
 
 via clamp-on CT'svia terminals
Voltage0.1%0.1%
Current0.3% (0.1A~1000A)
Long term accuracy assured (1A~40A)
0.1% (0.1A~10A)
Power0.3%
Long term accuracy assured (1A~40A)
0.1%
Active power0.3%
Long term accuracy assured (1A~40A)
0.1%
 
0.1%
Reactive power0.5%0.3%
Harmonic2nd ~51st0.1%
Integrated virtual loadOutput current: 10A, power: 20VA
Others
Internal virtual loadOutput current: 20A, power: 20VA
Constant of pulseFL=3.6×104P/KWh FH=3.6×108P/KWh