DC High Voltage Generator Power Supply lmpulse Voltage Cable Hipot Tester
Overview:
To perform closed adjustments with high voltage stability, little ripple, and a quick, dependable protection circuit, High Voltage DC Withstand Voltage Hipot Tester uses high frequency pulse width modulation (PWM) technology. The broad temperature LCD panel uses green backlighting, allowing for good display in both bright and low light conditions. Dupont's novel filler substance is used in high-pressure components to increase product stability and dependability. Products are extensively utilized as regulated dc high voltage power supplies in electrical power supply departments, power transmission and transformation engineering firms, preventative testing of major industrial businesses, and scientific research institutes.
Features:
♦ The DC hipot tester utilizes high frequency PWM technology to perform closed adjustments with high voltage stability, little ripple, and a quick, dependable protective circuit. The generator can withstand direct discharge from high capacitance devices. It is portable for usage in the field because to its tiny size and low weight.
♦ Full range of linear smoothly adjusted voltage with voltage regulation accuracy less than 0.1%, voltage measurement accuracy of 0.5%, resolution of 0.1kv, and current measurement accuracy of 0.5%, minimum resolution of control box 1 A and shock resistance current of 0.1 A.
♦ The generator may be utilized at the site in any weather conditions because it uses an AC 220 V power source (AC220V10%, 50 hz1%).
♦ High voltage multiplier eliminates the drawbacks of air and oil-filled equipment by using Dupont materials for full solid encapsulation. It stands stably and is easier to maintain thanks to its wide base and light outer cylinder.
♦ Switch button for 75% MOA voltage, an easy-to-use testing arrester.
♦ The over-voltage setting function shows the over-voltage value during regulation; this function provides excellent protection against over-voltage, over-current, and short circuit discharge. The ideal ally for cable experimentation is this.
♦ The operator and samples are always protected by the perfect break line and non-zero potential start protection mechanism. The general design of this product has a shock-proof control box, a simple, straightforward panel layout, and voice prompts for operation.
Technical Parameters:
Model | GDF-60/2 | GDF-120/2 | GDF-120/5 | GDF-200/2 | GDF-300/2/3 |
Output Voltage | 60kV | 120kV | 120kV | 200kV | 300kV |
Output Current | 2mA | 2mA | 5mA | 2mA | 2mA/3mA |
Output Power | 120W | 240W | 600W | 400W | 600W/900W |
Double Voltage Unit Size | 145*500mm | 145*800mm | 145*800mm | 145*1000mm | 145*1300mm |
Operating Unit Size | 360*260*245mm | ||||
Total Weight | 10kg | 15kg | 17kg | 20kg | 25kg |
Riple Coefficient | Less than 0.5% |