Soft Starter 22kw/380VAC for Livestock Farms to Run Pumps

Min.Order: 1
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 111 ~ 121

Description
Soft Starter 22kw/380VAC for Livestock Farms to Run Pumps


Our customers use soft starter for livestock farms to run pumps.Very popular!!!

Of course ZJR2 Series Soft Starter motor also applies to centrifuges,blower,compressor,transport planes,mixer,rolling ball mill broken machines and mechanical equipment motor starter.

ZJR2 series meet our customers' requirements:

Suit-----------------------   The soft starte is balance the current when the motor starts,only work when the motor is starting.


Economical---------------------- We are the manufacturer specialized in soft starter and inverter since 1998.Manufacturers mean better prices and faster shipping.Good after service.We support each of our customers and offer them competitive prices.Consideration for our customers is always our tenet.

It is easy to operate-------------------- All the software and hardware are researched and developed by CHZIRI engineers.We have instructions in English on how to use our soft starter.


ZJR2 Series from 5.5kw to 55kw the dimensition is same,please check below:



  CHZIRI can provide Russian keypad!!!



CHZIRI Soft start installation scene diagram.



DIMENSION:(UNIT:MM)
 
Soft starter ModelRated Power(KW)Rated Current (A)Outline SizeInstall SizeNet Weight
H1W1DH2W2d
ZJR2-32202244270145159245130M6<3.5

Technical Indications
 
ItemItem Description
Input Power SupplyInput VoltageThree Phase 380V-15% ~ 415+10%
Frequency50/60Hz
Adaptive MotorSquirrel-cage three-phase asynchronous motor
Starting TimesIt is recommended not to exceed 20 times per hour.
Control Mode1) Operation panel control; 2) Operation panel + external control; 3) External control; 4) External control + COM control; 5) Operation panel + external + COM control; 6) Operation panel + COM control; 7) COM control; 8) No start or stop operation.
Start Mode1) Current-limiting start; 2) Voltage ramp start; 3) Kick start + current-limiting start; 4) Kick start + voltage ramp start; 5) Current ramp start; 6) Voltage current-limiting double closed-loop start.
Stop Mode1) Soft stop; 2) Free stop.
Protective Function
Open loop protection for external instantaneous stop terminals; 2) Over-heat protection for soft starter; 3) Protection for too long starting time; 4) Input open phase protection; 5) Output open phase protection; 6) Unbalanced three-phase protection; 7) starting over current protection; 8) Running overload protection; 9) Under voltage protection for power voltage; 10) Over voltage protection for power voltage; 11) Protection for fault parameter setting; 12) Load short circuit protection; 13) Auto restart or incorrect wiring protection; 14) Incorrect wiring protection of external control stop terminals.

Ambient
Place to be usedIndoor location with good ventilation free from corrosive gas and conductive dust.
AltitudeBelow 3000M. It have to rise the rate power when the altitude is more than 3000M.
Ambient
Temperature

-30~+55ºC
Ambient Humidity≤90%RH without dew condensation.
Vibration<0.5G
StructureProtection ClassIP20
Cooling PatternNatural wind cooling.


CHZIRI  Soft starter  Wiring Diagram:

Customers we've worked with

CE CERTIFICATE OF CHZIRI PRODUCT 





CUSTOMER SUPPORT
 
  • Email Customer Support:
  • 8:30am-:16:45pm  Sunday-Friday
  • All emails will be responded to within 12-24hours

RETURNS

Please note that all returns must be pre-approved by us.Unauthorized returns will not be accepted.If you need to return,please check twice to confirm the item not work and contact our customer service representative,let us know the detailed problem and send us some pictures for confirmation.
Scroll to Top