Radiant Panel Flame Spread Apparatus ASTM E 162

Min.Order: 1
Product origin: Chongqing, China
Infringement complaint: complaintComplaint
US$ 2000 ~ 10000

Description
Radiant Panel Flame Spread Apparatus ASTM E 162 

Introduction:

Radiant panel flame spread tester uses a gas heat radiant panel to test the flammability of building surface materials (ASTM E162) and foam plastic (ASTM D3675). The flame spread index (IS) is determined by factors such as flame spread and heat dissipation. It is used as a necessary parameter in many industry codes, especially for public transportation (trains and buses). Data collection and analysis are automatically completed by the software.

Standard:

• ASTM E 162: Standard test method for testing the flammability of the surface of materials using radiant heat energy
• ASTM D 367: Standard test method for flammability of flexible porous materials using radiant heat energy

Feature:
1.  The frame structure is made of stainless steel; beautiful and corrosion-resistant;
2.  The reflector is made of cast iron frame. The surface of the reflector is made of porous fireproof material with a size of 305X457mm. The working temperature is 815 ºC.
3.  The filter is equipped with a fan to supply air to the reflector.
4.  The device has a pilot lighter, electronic ignition, automatic flameout safety monitoring device
5.  There is an observation point every 3 inches on the stainless steel sample holder for observing the progress of the flame front.
6.  The pyrometer can measure the surface temperature of the radiation plate, including the bracket. The temperature can reach 815 ºC.
7.  Stainless steel sample holder and pilot burner device.
8.  Airflow meter, gas control valve to control the mixing of gas sent into the radiant panel;
9.  The stainless steel exhaust pipe has a detachable part, which is convenient for cleaning the thermocouple. The exhaust pipe is equipped with 8 thermocouples according to the standard.
10.  The calibrated burner has 1.8mm holes in 16 different angles and needs to be along the centerline.
11.  To control the surface temperature of the reflector, the blackbody temperature of 180 ° C ~ 230 ° C needs to be set to an accuracy of ± 5 ° C. It is suitable for observing the surface temperature of a reflector with a surface radius of 250MM outside 2M.
12.  An insulated thermocouple is attached to measure the temperature of the stack.
13.  Imported heat flow meter (round foil type) to test the heat radiation condition of the radiation plate (0 ~ 100kW / m2).
14.  DAQ system can realize automatic control and measurement.
15.  Gas safety control and circuit cut-off device.

Control system:
1. Independent electrical control cabinet.
2. Standard control cabinet, computer + Labview intelligent control system.
3. Intelligent system test and easy operation.
4. Imported gas flow meter to accurately control gas flow.
5. Automatic radiation calibration, automatic control of experimental radiation.
6. The flow of the exhaust fan is 0.5m / s.
7. Experimental data is automatically saved and can be printed freely.


Product Image:




Specification:
ModelGD-ASTME162
Size1,850(W)×700(D)×1,260(H)mm
Console Size600(W)×750(D)×1600(H)mm
PowerAC 220V, 50/60Hz, 15A
Weight150kg
Instruction manualprovide
ExhaustMin 15 m3/min
ToolsPropane gas, desktop computer
Scroll to Top