ITEMS | SPECIFICATIONS | |
Design standard | BS EN 13355: 2004 + A1: 2009 BS EN 60204: 2006 + A1: 2009 | |
Internal dimensions | 6000 x 4000 x 2650mm (L x W x H) | |
External dimensions | 7010×5400×3410mm(L×W×H ) | |
Plenum | 400mm high | |
Basement | 300mm high | |
Entrance door | 1 set, 3200×2600 mm (W×H) | |
Personnel door | 1set, 800 X 2000mm (W X H) | |
Walls | 50mm rock wool panels | |
Ceiling lighting (LED) | 8 sets, each 4 X18W, 576W total | |
Brightness | >700LUX | |
Filters | Pre-filter, floor-level filter, exhaust filter | |
Air intake | Direct-type turbine fan, 5.5KW CE motor | |
Air exhaust | Direct-type turbine fan, 5.5KW CE motor | |
Air volume | 22,000m3/h | |
Empty loaded air speed | +/-0.22m/s | |
Maximum working temperature | 80ºC | |
Heat exchanger power | 200KW | |
Controls | CE standard control box | |
Rated power | 45KW | |
NOISE | <78dB |