Items | S2100S | |
Input | Rated voltage,Frequency | 1PH/3PH AC 220V 50/60Hz,3PH AC 380V 50/60 Hz |
Voltage Range | 220V: 170V-240V, 380:330V-440V | |
Output | Voltage Range | 220V:0-220V;380V:0-380V |
Frequency Range | 0.10~400.0 Hz | |
Control method | V/F control,Space verctor control | |
Indication | Operating status/Alarm definiton/interactive guidance;eg,frequency setting,the output frequecy/current,DC bus voltage,the temperature and so on. | |
Control Specification | Output Frequency Range | 0.10~400.00 Hz. |
Frequency Setting Resolution | Digital input: 0.01 Hz. Analog input:0,1% of maximum output frequency | |
Output Frequency Accuracy | 0.01 Hz. | |
V/F Control | Setting V/F curve to satisfy various load requirements | |
Torque Control | Auto increase:auto riase torque by loading condition;Manual increase:enable to set 0.0~20% of raising torque | |
Multifunctional Input Terminal | 8 multi-function input terminals,realizing fuctions including fifteen section speed control,program running, four-section acceleration/deceleration speed switch,UP/DOWN function and emergency stop and other functions | |
Multifunctional Output Terminal | 3 multi-function output terminals for displaying of running,zerospeed,counter,external abnormity,program operation and other infornation and warnings | |
Other functions | PID control | Built-in PID control |
RS485 | Standard RS485 communication function(MODBUS) | |
Frequency setting | Analog input:0-10v,4 to 20mA can be selected; Digital input:input using the setting dial of the operation panel or RS485 or UP/Down Note:AVI terminals can be used to select and analog voltage input (0-10v) and analog current input (4-20mA) through the switch J2. | |
Multi-speed | Four multifunction input terminals,15 section speed can be set. | |
Automatic voltage regulation | Automatic voltage regulation function can be selected | |
Counter | Built-in 2 group of counters | |
Protection Warning Function | Overload | 150%,60 second(Constant torque) |
Over Voltage | Over voltage protection can be set | |
Under Voltage | Under voltage protection can be set | |
Other protections | Output shortcircuit,over current,and parameter lock and so on. | |
Environment | Ambient Temperature | -10°C to 40°C(non-freezing) |
Ambient Humidity | Max. 95%(non-condensing) | |
Altitude | Lower than 1000m | |
Vibration | Max. 0.5G | |
Structure | Cooling Mode | Forced air cooling (5.5kW or more) |
Protective Structure | IP65 |
Model | Suitable | Output | Assembly Dimension(mm) | |||||
Motor | Current | W | H | D | A | B | b | |
S2100-2S0.75GS | 0.75KW | 5 | ||||||
S2100-2S1.5GS | 1.5KW | 7 | 188 | 122 | 134 | 105 | 178 | M4 |
S2100-2S2.2GS | 2.2KW | 11 | ||||||
S2100-4T0.75GS | 0.75KW | 2.7 | ||||||
S2100-4T1.5GS | 1.5KW | 4 | 188 | 122 | 134 | 105 | 178 | M4 |
S2100-4T2.2GS | 2.2KW | 5 | ||||||
S2100-4T3.7GS | 3.7KW | 8.6 | ||||||
S2100-4T5.5GS | 5.5KW | 12.5 | 235 | 154 | 179 | 125 | 221 | M4 |
S2100-4T7.5GS | 7.5KW | 17.5 | ||||||
S2100-4T11GS | 11KW | 24 |