Vg70 Hospital ICU Ventilator Pneumatic Driven Electronic Control ICU Turbine Ventilator

Min.Order: 50
Product origin: Guangzhou, Guangdong, China
Infringement complaint: complaintComplaint
US$ -1

Description
VG70 Hospital ICU Ventilator Pneumatic Driven Electronic Control ICU Turbine Ventilator


Superior Mobile ICU ventilator
• Comprehensive ICU ventilator including BIVENT and PRVC
• Compact, big capacity battery, no air compressor, intra-hospital mobility
• Flexible device configuration: equipped on a trolley, bed or ceiling pendant
Cost Effective Solution
• Unique metal-based, autoclavable, heated exhalation valve
• Built-in flow sensor, non-consumable design
• Upgradeable ventilation system software, with an available USB port
 
An Optimal Combination of Invasive and Noninvasive Ventilator
As noninvasive ventilation is used increasingly in a wide range of clinical situations, we offer a dual solution. VG70 combines the advantages of a flexible noninvasive ventilator with a full-featured invasive ventilator for the ICU.

 
Ventilation Settings 
Ventilation Modes• VCV (A/C), PCV (A/C), PRVC (optional), PSV (optional), STANDBY • SIMV (VCV)+PSV, SIMV (PCV)+PSV, SIMV (PRVC)+PSV
• SPONT/CPAP+PSV
• BIVENT/APRV +PSV (optional)
• NIV/CPAP, NIV-T, NIV-S/T
Enhancements• Apnea ventilation, Pressure and Flow trigger, Automatic Tube Compensation (ATC), Smart suction • Manual breath, Insp/Exphold, Screen freeze, Nebulization, Lung recruitment
Parameters 
Tidal volume (VT)20-2000ml
Respiratory rate (RR)1 to 80 bpm
Inspiratory time (Ti)0.2 to 9 s (adult), 0.2 to 5 s (pediatric)
Inspiratory flow (Flow)0 to 100 L/min (pediatric), 0 to 180L/min (adult)
Inspiratory pressure(Pinsp)5 to 70 mbar (or cmH2O)
Inspiratory pressure limit(Pmax)80 mbar (or cmH2O)
PEEP0 to 35 mbar (or cmH2O)
Tslope0 to 2 s
O2 concentration(FiO2)21 to 100 Vol%
Trigger sensitivity0.5 to 20 L/min (Flow trigger),
-20 to 0 mbar (or cmH2O) (Pressure trigger)
I/E ratio1/10 to 4/1
Apnea alarm time10-60 seconds
Monitoring• Inspiratory O2 concentration (FiO2), End-expiratory CO2 concentration (etCO2)
• Compliance (dynamic & static), Resistance (R), MVleak, RSBI, WOB, I:E, Vdaw, PEEPi • Pressure-Volume loop, Pressure-Flow loop, Flow-Volume loop
AlarmsExpiratory minute volume (MV) High/Low, Airway pressure (Paw) High/Low,
VTe Low, PEEP High/Low, Insp. O2 concentration (FiO2) High/Low,
End-expiratory CO2 concentration (etCO2) High/Low, fspont High, Apnea alarm, Disconnection, Flow sensor error, Gas supply, Electrical supply & battery failure,
Exhalation obstruction, Apnea backup for low frequency alarm
Dimensions (WxDxH)375mm x 395mm x 430mm
Weight17kg (37.5lbs)
Screen12.1" TFT color touch screen

 





Product Tag:
Related categories: