Product Construction
Fiber:
2-24 fibers
Uni-loose tube gel-filled
Armor:
Steel wire
OuterJacket:
Black UV-and moisture-resistant polyethylene (PE)
Features
Applications
Optical Charateristics
Fiber Type | G.652 | G.655 | 50/125 um | 62.5/125 um | |
Attenuation (+20X) | 850 nm |
|
| <3.0 dB/km | <3.3 dB/km |
1300 nm |
|
| <1.0 dB/km | <1.0 dB/km | |
1310 nm | <0.36 dB/km | <0.40 dB/km |
|
| |
1550 nm | <0.22 dB/km | <0.23 dB/km |
|
| |
Bandwidth | 850 nm |
|
| >500 MHz-km | >200 Mhz-km |
1300 nm |
|
| >500 MHz-km | >500 Mhz-km | |
Numerical Aperture |
|
| 0.200±0.015 NA | 0.275±0.015 NA | |
Cable Cut-off Wavelength cc | <1260 nm | <1450 nm |
|
|
Structure and Technical Specifications
Fiber Count | Nominal Diameter (mm) | Nominal Weight (kg/km) | Allowable Tensile Load (N) | Allowable Crush Resistance | ||
Short Term | Long Term | Short Term | Long Term | |||
2~24 | 10.6 | 200 | 8000 | 4000 | 3000 | 1500 |
Note : This datasheet can only be a reference, but not a supplement to the contract. Please contact our sales people
for more detailed information.
We produce and test cable comply with following standard:
Mechanical Performance | |
Max Tension Performance | IEC 60794-1-2-E |
Max. Operation Tension | IEC 60794-1-2-E1 |
Crush Test | IEC 6079 -1-2-E3 |
Impact Test | IEC 60794-1-2-E4 |
Repeated Bending | IEC 60794-1-2-E6 |
Torsion Test | IEC 60794-1-2-E7 |
Cable bend | IEC 60794-1-2-E11A |
Attenuation Coefficient | ITU-T G.652 |
Structural Test | IEC-60793-1-20 |
Environmental Performance | |
Temperature Cycling | IEC 60794-1-2-F1 |
Water Penetration | IEC 60794-1-2-F5B |
Filing Compound Flow | IEC 60794-1-E14 |
You May Like