10mA 6000A Three Phase Energy and Power Quality Analyzer

Min.Order: 1
Product origin: Wuhan, Hubei, China
Infringement complaint: complaintComplaint
US$ 1000 ~ 2500

Description
General Information:
EPCR-4000 Power Quality Analyzer is specially designed for field test of three phases, multi-functional and intelligent, concise man-machine opera-tion. It is easy to use, large LCD screen display, high resolution, interface in English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current volt-age,  maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, trans-former K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc. Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data.
In the current power applications, more and more large power equipment, power grid fault have become more and more complex, with development of the industry, it put forward high request more and more to quality that electric energy. We provide this power quality analyzer for that, which you can troubleshoot of complex power system more quickly and accurate, and monitoring and maintenance of power quality parameters more com-prehensive and systemic.
EPCR-4000 Power quality analyzer adopt DSP + ARM double processor architecture, DSP is use for data collection and the processing of algorithm, the ARM is use for the communication protocol and the man-machine interface processing. Analog signal acquisition is by 2 pieces ADC Chip of ADI company. Resolution for ADC Chip is 16 bit and it is 4 channel synchronous sampling. The highest sampling rate can reach 1 MSPS, to ensure the accuracy of the channel and the information integrity, and wouldn't miss any transient changes in the grid, can more ac-curate to detect the transient waveform rising and dropping drastically, and waveform instantaneous interrupt; DSP working frequency is over 200 MHZ, to be able to timely monitoring of the power grid and dynamically ad-just the sampling frequency to realize synchronization of power frequency and sampling frequency; Using a 5.6 -inch LCD color screen display, a resolution of 640 dots x 480 dots, with different display color difference be-tween the parameters of phase, waveform, vector diagram, harmonic ratio, the user can be more efficient and more intuitive understand the state of power grid parameters. Built-in flash memory can store 60 group of screenshots at the same time, 150 groups of capture transient voltage/current waveform figure, and 12800 groups of alarm list. Starting current detection model can continuously capture starting current waveform for 100 s. Built-in 2G memory card to store the trend curve record, simultaneous recording 20 parameters (can choose according to need) collect data for once every five seconds, trend curve records can be stored for 300 days.
Power Quality Analyzer also named: Intelligent Three Phase Power Quality Analyzer, Multifunctional Power Quality Analyzer, which simultaneous with the functions of harmonic Analyzer, phase volt-ampere meter, electric parameter tester. It applies to electricity industry, petrochemical, metallurgy, railway, mining enterprises, scientific research institution, metrological department. Especially suitable for comprehensive analysis and diagnosis on all the voltage, current, power, power, harmonic, phase electric parameters.
 

Functions:

Basic function

Waveform real-time display (4 channels voltage/4 channels current).
True RMS values of voltages and currents.
The DC components of voltages.
Peak current and voltage values.
Minimum and maximum half-cycle RMS current and voltage values.
Pharos diagram display.
Measurement of each harmonic up to order 50.
Bar charts show harmonic ratios of current and voltage of each phase.
Total harmonic distortion (THD).
Active, reactive, apparent power, by phase and cumulative.
Active, reactive, apparent energy, by phase and cumulative.
Transformer K factor.
Power factors (PF) and displacement factors (DPF or COSΦ).
Short-term voltage flicker (PST).
Three phase unbalance(current and voltage).
 

Capture function

Transient capture function
Monitoring instantaneous change of power grid voltage current parameters, including the voltage current fluctuations, voltage current surge, sag and short supply interruption, temporary overvoltage, impact current and Current voltage instantaneous distortion. Instruments can store 150 sets of transient waveform at the same time.
Starting current monitoring
Monitoring surge current of line and the startup current when electrical equipment is starting, help to correctly design capacity. Can be display the RMS rising / falling curve In the startup process, the envelope curve of startup current, waveform of 4 channels current and 4 channels voltage. Recording about 100s after trigger, storage the current /voltage instantaneous and waveform curve of each cycle in 100s.
Trend chart recording and storing function
Store all the test parameters of basic test functions (Urms, Uthd, Ucf, Uunb, Hz, Vrms, Vthd, Vcf, Vunb, PST, Arms,  Athd, Acf, Aunb, KF,W, VAR, VA, PF, COSφ, TANφ),50 voltage harmonics, 50 current harmonics. And create the trend curve. Record data for a long time according to need(concurrent selection 20 parameters to record data for once every five seconds, you can record about 300 days.).
Alarm function
Set the limit values according to need, monitoring the values whether overshoot, if overshoot will generate an alarm log, such as: voltage, current, unbalance, harmonic ratio, frequency, active power, total harmonic distortion. You can configure 40 different alarms, each group can set different monitoring parameters (including 50 harmonics, total of 123 different parameters) and limit values, also can set the shortest time of overshoot. The log can contain up to 12,800 alarms.
Snapshot function
Any screen can be saved (screen snapshot), at the same time automatically records the time and test mode. Such as can save voltage and current waveform, harmonic bar chart, phasor diagram etc. It can save a maximum of 60 screen snapshot.

 

Other functions

Communication function
Communicate with computer via USB; Monitoring software can display waveform of power quality analysis, read of the transient waveform, trend chart recording, alarm log, screenshots, and display on the computer.
Setting function
The user can configuration of the time and date, configuration of the screen contrast and brightness, definition of each phase curve colors.
Choice of type of connection to the net work.
Configuration of the type of the current sensors and voltage ratios.
Select Chinese menu or English menu.
Help menu in English
Every stage of operation can press the "help" key to obtain relevant information.

Technical specifications:

Base condition and working condition

Influence factorTest itemBase conditionWorking condition
Environment temperatureAll parameters(23±2)°C-10°C~ 40°C
Relative humidityAll parameters40%~ 60%<80%
Phase-to-neutral voltageAll parameters(100±1%)V1.0V~ 1000V
Phase-to-phase voltageTrue RMS phase-to-phase voltage(200±1%)V1.0V~ 2000V
CurrentTrue RMS current(5±1%)A10mA~ 6000A
Network frequencyAll parameters50Hz±0.1Hz40Hz~ 70Hz
Phase shift Active power and active energyCosφ=1Cosφ: 0.2~ 1.0
Reactive power and reactive energySinφ=1Sinφ: 0.2~ 1.0
HarmonicAll parameters<0.1%0.0%~ 100%
Voltage unbalanceAll parameters<10%0.0%~ 100%
Working voltage of deviceAll parametersDC9.8V±0.1VDC9.5V~ 10.5V
External electric field, 
magnetic field
All parametersShould be avoided
Test positionMeasured related parameters of currentTested wire at the center of clamp.

General specification

Power supplyRechargeable lithium-ion battery packs 9.6V, backup charger.
Battery indicatorBattery symbol      shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute.
Power consumptionCurrent consumption of normal test 490 mA, continuous working for 10 hours.
Display modeLCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm.
Size of clampFR008 small sharp current clamp: 8mm×15mm;
FR020 circle current clamp: 20mm×20mm;
FR050 circle current clamp: 50mm×50mm.
FR300R Flexible Coil Current Sensor (with Integrator) : Ф300mm
Instrument dimensionsL×W×H: 277.2mm × 227.5mm × 153mm.
Number of channels4U/4I.
Phase-to phase voltage1.0V~2000V.
Phase-to-neutral voltage1.0V~1000V.
CurrentEPCR480 current clamp: 10mA~10.0A;
EPCR420 current clamp: 0.10A~100A; (option)
EPCR450 current clamp: 1.0A~1000A; (option)
EPCR600R Flexible Coil Current Sensor (with Integrator) : 10A ~ 6000A  (option)
Frequency40Hz~70Hz.
Parameters of electricityW, VA, Var, PF, DPF, cosφ, tanφ.
Energy parametersWh, Varh, Vah.
HarmonicOrder 0~50.
Total harmonic distortionOrder 0~50, each phase.
Expert modeYes.
Number of Transient records150 sets.
Voltage flickerYes.
Starting current modeYes, 100 seconds.
3 phases unbalanceYes.
Record300 days(simultaneous recording 20 parameters, record one point every 5 seconds).
Min/Max recorded valueMeasurement of maximum and minimum values over a period of time.
Alarm40 different types of parameter selections, 12,800 sets alarm logs.
PeakYes.
Phasor diagram displayAutomatically.
Capacity of snapshots60.
Menu languageEnglish/Chinese.
CommunicationUSB.
Automatic switching offWhen an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off.
In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.
Backlight functionYes, suitable for use at night and dark place.
WeightHost: 1.6kg (with battery).
FR008 small sharp current clamp: 168g×4;
FR020 circle current clamp: 252g×4;
FR050 circle current clamp: 463g×4;
FR300R Flexible Coil Current Sensor (with Integrator) : 280g×4;
Test wires and power adapter: 800g;
Total weight: about 10.8kg (with packaging).
Length of voltage test wire3m.
Length of current sensor wire2m.
Working temperature and humidity-10°C~40°C; below 80%Rh.
Storage temperature and humidity-10°C~60°C; below 70%Rh.
Input impedanceInput impedance of test voltage: 1MΩ.
Withstand voltageWithstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell.
InsulationBetween instrument wiring and shell ≥10MΩ.
StructureDouble insulation, with insulation vibration-proof sheath.
Safely rulesIEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.
 

Instrument precision (excluding the current sensor)

Respectively introduce the following data (on the basic of base conditions and the ideal current sensors, perfectly linear, no phase shift).
MeasurementRangeDisplay resolutionThe maximum error in the range of the reference
Frequency40Hz~ 70Hz0.01Hz±(0.03)Hz
True RMS phase-to-neutral voltage1.0V~ 1000VMin resolution 0.1V±(0.5%+5dgt)
True RMS phase-to phase voltage1.0V~ 2000VMin resolution 0.1V±(0.5%+5dgt)
DC voltage1.0V~ 1000VMin resolution 0.1V±(1.0%+5dgt)
True RMS current10mA~ 6000AMin resolution 1mA±(0.5%+5dgt)
Peak of phase-to-neutral voltage1.0V~ 1414VMin resolution 0.1V±(1.0%+5dgt)
Peak of phase-to-phase voltage1.0V~ 2828VMin resolution 0.1V±(1.0%+5dgt)
Current peak10mA~ 8484AMin resolution 1mA±(1.0%+5dgt)
Peak factor1.00~ 3.990.01±(1%+2dgt)
4.00~ 9.990.01±(5%+2dgt)
Active power0.000W~ 9999.9kWMin resolution 0.001W±(1%+3dgt)
Cosφ≥0.8
±(1.5%+10dgt)
0.2≤Cosφ<0.8
Reactive power, inductive or capacitive0.000VAR~
9999.9kVAR
Min resolution 0.001VAR±(1%+3dgt)
Sinφ≥0.5
±(1.5%+10dgt)
0.2≤Sinφ<0.5
Apparent power0.000VA~
9999.9kVA
Min resolution 0.001VA±(1%+3dgt)
Power factor-1.000~ 1.0000.001±(1.5%+3dgt)
Cosφ≥0.5
±(1.5%+10dgt)
0.2≤Cosφ<0.5
Active energy0.000Wh~ 9999.9MWhMin resolution 0.001Wh±(1%+3dgt)
Cosφ≥0.8
±(1.5%+10dgt)
0.2≤Cosφ<0.8
Reactive energy, inductive or capacitive0.000VARh~
9999.9MVARh
Min resolution 0.001VARh±(1%+3dgt)
Sinφ≥0.5
±(1.5%+10dgt)
0.2≤Sinφ<0.5
Papparent energy0.000VAh~
9999.9MVAh
Min resolution 0.001VAh±(1%+3dgt)
Phase angle-179°~ 180°±(2°)
Tanφ
(VA≥50VA)
-32.76~ 32.76Min resolution 0.001φ:±(1°)
Phase shift of power factor
(DPF)
-1.000~ 1.0000.001φ:±(1°)
Harmonic ratio
(order 1 to 50) (Vrms>50V)
0.0%~ 99.9%0.1%±(1%+5dgt)
Harmonic angle
(Vrms>50V)
-179°~ 180°±(3°) harmonics of order 1 to 25
±(10°) harmonics of order 26 to 50
Total harmonic ratio
(THD or THD-F)≤50
0.0%~ 99.9%0.1%±(1%+5dgt)
Distortion factor
(DF or THD-R)≤50
0.0%~ 99.9%0.1%±(1%+10dgt)
Transformer K factor1.00~ 99.990.01±(5%)
3 phases unbalance0.0%~ 100%0.1%±(1%)

Current sensor character

Type of current sensorTrue RMS currentMax error of true RMS currentMax error of phase angle
 EPCR480 current clamp10mA~ 99mA±(1%+3dgt)±(1.5°),Arms≥20mA
100mA~ 10.0A±(1%+3dgt)±(1°)
EPCR420 current clamp0.10A~ 0.99A±(1%+3dgt)±(1.5°)
1.00A~ 100A±(1%+3dgt)±(1°)
EPCR450 current clamp1.0A~ 9.9A±(2%+3dgt)±(3°)
10.0A~ 1000A±(2%+3dgt)±(2°)
EPCR600 Flexible Coil Current Sensor (with Integrator) 10A~199A±(1 % + 3dgt)±(3°)
200A~6000A±(1 % + 3dgt)±(2°)


More details on Power Quality Analyzer please contact EP Hipot Electric, we have professional tech team to design correctly designed products and systems.




Product Tag:
Related categories:
Scroll to Top