Wireless Condition Monitoring Sensor for Cooling Fan

Min.Order: 2
Product origin: Hefei, Anhui, China
Infringement complaint: complaintComplaint
US$ 300 ~ 700

Description
Look for distributors

Working Diagram:





 
System Features:

1. All channels synchronous collection
2. One sensor collects both vibration and temperature
3. Alarm SMS/EMAIL for both vibration and temperature data
4. Intelligent alarm: minimal sampling value(RMS) interval  5min, good coverage of machine operation
5. Wireless work mode, no need wiring work, saving wiring cost,
Easy to Install
6. Multiple communication options
7. Convenient installation
RONDS IWMS has no signal cable during installation, 2 years battery life of wireless accelerometer, secure installation of accelerometer with magnet base and M6 bolt. Satisfy the requirement of explosion proof degree on site
8. Four in one sensor--vibration and temperature integrated sensor
Integrated design, synchronous collection of acceleration, velocity and displacement and temperature


Technical Parameters
Triaxial RH605 Wireless Vibration and Temperature Integrated Sensor
Vibration Measurement Parameter
Vibration RangePiezoelectric:±50 g(peak value)
MEMS:±16 g (peak value)
Linearity1%
Frequency Range (±3dB)Piezoelectric:2Hz-20000Hz(±3 dB)
MEMS:2-1000Hz(±3 dB)
Measuring definition acquisitionPiezoelectric direction time waveform length:1K,2K,4K,8K,16K,32K,64K,128K
MEMS direction time waveform length:1K,2K,4K,8K,16K
Analysis frequencyPiezoelectric:500Hz,1000Hz,2000Hz,5000Hz,10000Hz,20000Hz
MEMS:500Hz,1000Hz
Long time waveform acquisitionPiezoelectric direction time waveform length:256K,512K,1M,2M
Analysis frequency:5000HZ,10000HZ,20000HZ
Temperature Measurement Parameter
Temperature Range-40~125 ºC
Temperature Accuracy±1 ºC (-40ºC~125ºC)
Electrical and Structure Parameter
Power SupplyLithium-thionyl chloride battery
Communication Method2.4GHz IEEE 802.15.4
Dimension46.5 mm × 93.6 mm(diameter × height)
Weight210 g
Environment Parameter
Working Temperature-40~70 ºC
IP gradeIP68
One Axial RH505 Wireless Vibration and Temperature Integrated Sensor
Vibration Measurement Parameter
Vibration Range±50 g
Linearity1%
Frequency Range (±3dB)2~20kHz
Sampling rate1280Hz~51.2kHz
Analysis frequency500Hz,1kHz,2kHz,5kHz,10kHz,20kHz 
Waveform Length1K,2K,4K,8K,16K,32K,64K,128K
Lines400,800,1600,3200,6400,12800,25600,51200
Long time waveform Maximal length 2M
Temperature Measurement Parameter
Temperature Range-40~125 ºC
Temperature Accuracy±1 ºC (-40ºC~125ºC)
Electrical and Structure Parameter
Power SupplyLithium - thionyl chloride battery, 3.6V, 3.3Ah
Communication Method2.4GHz IEEE 802.15.4
Dimension46 mm × 94 mm (Diameter * Height)
Weight188 g
Environment Parameter
Working Temperature-40~70 ºC
IP gradeIP68
RH560 Wireless data collector
Input and output
Communication with Sensor2.4GHz IEEE 802.15.4
Indicator LEDTotal 3 pieces 
(working, communication, abnormal status)
Number of RH505 connecting30~60 units according to real application condition
Electrical and Structure Parameter
Power Supply220V AC 
Dimension203 mm × 82 mm × 260 mm  (Length * Width * Height)
Weight3 kg
MountingHanging or fixation through holder
Environmental Parameter
Working Temperature-40~70 °C
IP gradeIP66

MOS3000 Software



Site Installation





Application Industrial Fields




Application Industrial Fields






Ronds Global Market Performance 


 






















Contact 

Kelly Xu
 
 
 
Web: ronds5335195.en.made-in-china.com


















Product Tag: