LPDC Machine Technology Specification |
Parameter | Unit | J452L | J455L | J458L |
Machine body |
Fixed columns clearance | mm | 1050*750 | 1400*1000 | 1750*1250 |
Distance between mobile and fixed platen | mm | 450-900 | 500-1350 | 550-1800 |
Side cylinder stroke | mm | 250 | 300 | 450 |
Opening force of the upper cylinder | KN | 122 | 177 | 245 |
Closing force of the upper cylinder | KN | 94 | 138 | 305 |
Opening force of side cylinder | KN | 59 | 94 | 165 |
Closing force of side cylinder | KN | 78 | 122 | 212 |
Ejection force | KN | 122 | 177 | 305 |
Holding furnace |
Furnace type | | crucible | crucible or refractory |
Capacity | KG | 300 | 500 | 800 |
Power rate | KW | 20 | 30 | 40 |
Temperature control accuracy | ±ºC | 2 | 2-5 |
Furnace pressure | Bar | Max. 1.5 bar |
Hydraulic pump station system |
Motor type (Regulation or Servo) | | optional |
Motor power rate | KW | 5.5 | 15 | 18.5 |
Hydraulic pressure | Bar | Min. 80 bar -max. 120 bar |
Pump type (gear or plunger) | | Optional |
Cooling type | | Air | Air or water | Water |
Cooling water consumption | L/Min | | 40 | 50 |
Operation control system |
PLC, HMI unit | | Siemens |
Operation method | | Automatic |
Main power voltage (380V 60HZ,400V 50HZ) | V, HZ | Optional |
Auxiliary power voltage | V, HZ | 24 |
Control cabinet cooling type | | Fan | Fan or air conditioning |