Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems

Min.Order: 1
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 1000 ~ 40000

Description
1.Application of scroll commercial air cooling water chiller
Eurostars air cooling water chiller can supply domestic/commercial room cooling. 
Wide Range of Applications: air to water water chilles could meet the space cooling requirements of different places, such as villas, families, schools, factories, hotels, hospitals, etc.


2.Eurostars Commercial Air Cooling Scroll Water Chillers Features:
Eurostars air cooling water chillers are designed for commercial cooling. They have the following important features: 
--- Efficient and Energy-saving 
---Green and Environmental Protection
By using air source energy and electric power, there is no harmful gas being discharged during the operation of heat pumps. R410A and R407C refrigerant guarantees fluoride-free emission. 
---All-weather Operation
Stable operation without being influenced by windy, rainy or snowy weather. 
---Endurable 
Copeland or other famous brand scroll compressor, famous brand electronic expansion valve, Eaton/ Schneider/FUJI AC contactor and thermal relay as well as other brand components of the water chiller guarantee high product quality and a long lifespan. All of our screws and clips (both external and internal) are rust resistant , stainless steel is optional. The cabinet we are using is made of galvanized steel, making the product more rust resistant and durable.
 ---Multiple Protections
Eurostars water chiller with multiple protections: For example, if water flow is not enough in the system, the system will show high pressure protection and stop the water chiller automatically to protect the compressor from being damaged. Also, there is high current protection: if the power supply is not stable, the chiller will show the high current error to stop the heat pump and avoid compressor damage.
---Guaranteed Safety
Complete isolation of water and electricity avoids electric shock, explosion and poisoning. 
---Convenient: 
Air cooling water chillers are easy to install.


3.Air Cooled Scroll Commercial Water Chiller Technical Datas
Air Cooled Chiller Unit(commerical type)
Model     ESSA-05STN10DTN12DTN20QTN25QTN20DTN25DTN
Rated Cooling CapacityKW142834.558.2665867
USRT4.08.09.816.618.816.519.1
×1000 kcal/h12.024.129.750.156.849.957.6
RefrigerantR407C
EvaporatorTank Tube in Shell Shell and Tube
CondenserRipple Aluminum Fins around Cooper Pipe
          
Model     ESSA-25DTP40QTN50QTP80DTP100QTP160QTP
Rated Cooling CapacityKW66106130230290460
USRT18.830.137.065.482.5130.8
×1000 kcal/h56.891.2111.8197.8249.4395.6
RefrigerantR410AR407CR410A
EvaporatorShell and Tube 
CondenserRipple Aluminum Fins around Cooper Pipe

4.Air Cooled Scroll Water Chiller Main Components Introduction
(1)High Efficiency Scroll Type Compressor
---Flexible high-efficiency scroll compressor, which patent flexible design provides best ability of fluid-attack resistance and impurity tolerance.
---Continuous compression output ensure the pulse of air flow to be reduced, with low vibration noise


(2)High Efficiency Air Side Heat Exchanger
---Special shaped design, inner grooved patent sawtooth design and aluminum fin guarantee efficient heat exchange between the air side exchanger and ambient air.
(3)High Efficiency Water Side Heat Exchanger
---Tube in shell tank type: Optimize design of both inner and outer screwed tube, it helps to increase heating exchange efficiency, and provide better heating capacity. The special design of liquid refrigerant circulating tube on the bottom of condenser ensures the heat pump system run smoothly in severe working condition.
---Brazed-plate evaporator made from stainless steel features a brand-new diagonal design to better utilize heat exchanging surfaces.
---Shell and tube evaporator with inner grooved cooper tubes optimizes the cooling and heating efficiency.
Self-cleaning,high intensity,anti-shaking design and heat insulation covering material ensure shell and tube heat exchanger unstained,reliable,quiet,highly efficient.


(4)Throttling Device
Adopt superior quality famous exterior balanced thermal expansion valve or capillary type throttling device, which is high reliability and adjustability, can realize precise refrigerant and temperature control to ensure operating in precise and reliable status.


(5)Axial fan
Adopt famous brand axial fan,compact structure,which is accord with aerodynamic principles; falciform impeller which can assure it runs with high efficiency and low noise,also can keep a better aerodynamic performance even under a short air inlet condition.
(6)Intellectualized Controller
Adopt micro computer control, can operate via centralized manage system; whole system can realize remote operation. The system can monitor the water temperature, capacity status while running. The water temperature can be controlled according to the water outlet temperature.

5. EUROSTARS Commercial Air Coooling Scroll Water Chiller Series


6.About US
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services; which be always here to provide following service:
1) Project system design;
2) Technical support;
3) Manufacturing production;
4) Delivery;
5) Installation;
6) Test and commissioning;
7) Repair and maintenance;
8) After sale service, etc



7.FAQ
Q: What kind of Technical support Eurostars can provide?
Before selling
1. Set up customers file, and arrange professional sale engineers to introduce company products and services to customers in detail.
2. If customers are interested in our products, we will send professional technicians to survey the installation environment.
3. Make the solution according to different customers' requirements.

During selling
1. Machine installs and test by qualification engineers.
2. Ensure all the products we provided are qualified and new. The working life of the main engine is 15-20 years.
3. Construct and install the heat pump according to national relevant policies strictly, and ensure high quality delivery on time.
4. Test and debug the equipments strictly to ensure the safety and stability.
5. During the delivery, provide comprehensive and professional technical training on instructions and maintenance to customers.

After selling
1. We promise to offer free consulting call in 7×24 hours mode to solve the problems found in practice.
2. Products guarantee is 12~18 months from ex-factory date. Within 18months,if any components of your products damaged because of quality, we supply new replacement for free.
3. After the expiration of the quality assurance, we will continue to provide lifelong maintenance services, with just charging some cost price.


8.Customer visit us

9.Air cooled water chiller delivery or container loading


10. Installation instruction or installation photo, project photos



A,Place selection of installation Heat pump

 1). Heat pump should be installed in a large space, and have good air flow condition.
 2). Air inlet and outlet must be a clear road, the distance from barrier to inlet and outlet must be longer than 2m.
 3). Set drain ditch or drain outlet, so that can drain water easily.
 4). The installation base or bracket must be firm, make sure heat pump work balancely.
 5). Make sure heat pump is vertical, can't be slanted.
 6). Don't install heat pump at the place in where there is plenty of pollutional and corrosive gas or sand or fallen leaves.
 7). The installation place can't be near inflammable, flammable thing or fire.
 8). Installation:
---The installation base can be concrete construction, or steel bracket, and must use anti-vibration rubber pad, And the surface should be smooth.
---The design of installation base can be according to heat pump weight.
---The heat pump bottom should be fixed by bolt.
B,Pipe connection
The drain pipe and overflow pipe should be installed near drain ditch or drain outlet, easy to drain, and install drain water valve on drain pipe before magnetic valve there should be service valve on water pipe.
 If use plastic pipe (such as PPR pipe or ABS pipe), users should consider pipe expand and contract problem between heat pump and water tank.
 Water supply valve and cut-off valve maybe need insulation (according to local weather condition),avoid frost crack.
C,Water pipe system installation
Water pipe should be straight, and the arrange should be reasonable, reduce bend as little as possible. Reduce the water pipe resistance.
There can't be leaking at any place of pipe.
After all equipments and pipes installation finished, users should test water pressure, and drive air out, drain dirty out, make sure water cycle system is  clean. After confirm there is not any problem, then insulate all hot water pipes.
D,Power supply wiring
 220V heat pump use single phase power supply, 380V heat pump use three phase power supply, wire line is 3phase 4lines, A B C connects live line, N connects null line, E connect earth. Be sure not to connect N line to live line of power supply.
 1).When repairing, please turn power supply at "off" side.
 2).Power supply connecting process:make sure a equipment power supply is cut off before its installation is finished. Install power supply switch at suitable place, Use rubber hole for wiring line in electric box.
Power supply demand:
220V rated voltage±10%
380V rated voltage±10%
frequency:50Hz rated frequency±2%
 3).if power supply fluctuation is out of demand, please don't start your heat pump.



 