Standard Load Range | 6.5, 12.5, 25, 50, 85, 120, 200, 300, 400, 500 Tons |
Full Load Output | 1.5 nominal mV/V |
Excitation Voltage(Recommended) dc or ac | 10V |
Excitation Voltage(Max.) dc or ac | 15V |
Safe Service Load | 150% |
Proof Load | 200% |
Non Linearity | <1.0% |
Repeatability | <0.25% |
Output at zero Load | <+/-2.0% |
Input Resistance | 390+/-20 Ohms |
Output resistance | 350+/-5 Ohms |
Operational temperature range | -20 to +80 deg C |
Compensated temperature range | -10 to +50 deg C |
Temperature coefficient of zero | +/-0.010 %/deg C |
The temperature of the coefficient of span | +/-0.010 %/deg C |
Environmental protection | IP67 |
All percentages related to full rated load | |
Insulation | >2 at 100 V dc G Ohms |