High Pressure Hydraulic Piston A3H37 A3H56 A3H71 A3H100 A3H145 A3H180 A3H & AR22 AR16 A7H180 A7H265 Yuken A7H Pump
Yuken A7H Series High Pressure Variable Displacement Piston Pumps fetrue below:
High Pressure-Large Volume Displacement Adding to current A3H series, 180 and 270 cm3 /rev displacement with rated pres. 35MPa, Max. Pres. 40MPa pumps are now available.
Optional Through Drive Optional through drive allows an auxiliary or outboard pump (SAE Standard) to be directly mounted.
Fire-Resistant Fluids Water-Glycols and Polyol Ester Type are applicable under certain condition.
The correct choice of hydraulic fluid requires knowledge of the operating temperature in relation to the ambient temperature: in a closed circuit the circuit temperature. The hydraulic fluid should be chosen so that the operating viscosity in the operating temperature range is within the optimum range - the shaded area of the selection diagram. the higher viscosity class be selected in each case. i, e: At an ambient temperature of X °C an operating temperature of 60 °C is set. In the optimum operating viscosity range (shaded area) this corresponds to the viscosity classes VG47 or VG65; to be selected: VG64. and note: The case drain temperature, which is affected by pressure and speed, is always higher than the circuit temperature. At no point in the system may the temperature be higher than 100 °C. If the above conditions cannot be maintained due to extreme operating parameters, please consult us.