AJ-2103Anesthesia Machine, with its ergonomic design, integrates a concise and smooth structure and high mobility. The microcomputer-controlled Ventilator adopts exported sensors and other components. Its scientific and proper design as well as rigorous production process is what demonstrates the inner quality of Anjue products: mechanical ventilation is made secure and visible by the folded respiratory bellows, and the security of air supply is guaranteed by pneumatic transmission and measurement system. With multiple modern technologies applied, the Anesthesia Machine is both outstanding in performance and versatile in functions.
The Ventilator adopts microcomputer control with high-definition 5.7" LCD display, integrating the functions of respiratory control and displaying the monitoring parameters. It is versatile in function and excellent in performance.
The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose two kinds of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
High-definition four-tube flowmeter, designed with stoppers for oxygen and nitrous oxide to control the output oxygen concentration.
Reliable pneumatic transmission system.
Economic and proper configuration of technologies, optional as required by the Customer.
Modularized design and upgrading. Upgrading is available as required by the Customer.
TECHNICAL PARAMETERS Part of Anesthesia Machine Main bodyHigh-strength engineering plastic rack, light, beautiful and corrosion resistant Scope of application adult, child Gas source O2: 0.27~0.55MPa N2O: 0.27~0.55MPa Flow meterO2: 0.1~1.0L/min 1.1~10L/min N2O: 0.1~1.0L/min 1.1~10L/min O2, N2O linkage and N2O Stopper When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off. Flow rate of rapid oxygen supply 25~75L/min Low oxygen pressure alarm There will be sound alarm when the oxygen pressure < 0.2MPa Vaporizer it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane,Enflurane,Isoflurane and Sevoflurane,two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available. Respiratory circuitworking mode: all-close, semi-close, semi-open APL: 0.5~7 kPa Respiratory Bellows bellows for adults, bellows for children tidal volume range:0~1,500 ml
Part of Ventilator Display mode High-definition 5.7" LCD screen display Ventilation mode IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH Ventilation parametersTidal volume 50~1500 ml Rate 2~99 bpm SIMV rate 2~20 bpm I:E 2:1~1:8 Inspiratory trigger pressure -1.0~2.0 kPa PEEP 0~2.0 kPa Pressure range 1.0~6.0 kPa SIGH 1.5 times the inspiratory time Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway,pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure Monitoring of oxygen concentration (21%~100%) Security Alarm System Oxygen Concentration alarm upper limit setting range (50%~100%) low limit setting range (15%~50%) Airway pressure alarm upper limit setting range 1.0~6.0 kPa low limit setting range 0.4~2.0 kPa Per-minute ventilation volume alarm upper limit setting range 3.0~30L/min low limit setting range 1.0~10L/min Sustained high-pressure alarmit will give alarm when stress have consistently been higher than 2.5 kPa Suffocation alarm it will give sound and light alarm if there is no tidal volume input for 15 seconds Power alarm Power AC 220V±10% 50Hz±1Hz (UPS, Storage battery) Mechanical Arms) (End-expiratory CO2 monitoring) *Items within brackets are optional.