Medical Emergency Multi-Parameter Beside Portable 12 Inch Patient Monitor

Min.Order: 10
Product origin: Foshan, Guangdong, China
Infringement complaint: complaintComplaint
US$ 200 ~ 600

Description
Product Description                                                                                                                               
Item No.MO-001
Size46*39*45cm
Standard parameters5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.
G.W.12KG
Warranty1 year
Trade MarkMEDCO
After-Sale ServiceOnsite Training
Transport PackageAluminum-Plastic Box + Carton
MO-001


Multi-parameter Patient monitor

Features &Benefits:
  1. 12.1" color TFT display, high resolution: 800×600dpi;
  2. Separated para board: ECG, NIBP, SpO2 board;
  3. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob.
  4. Real time S-T segment analysis, and ARR analysis;
  5. SpO2 Pitch Tone Variation and Drug Dose Calculation;
  6. Parameter waveform and characters color selectable
  7. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
  8. Standby mode for Energy saving and suspend monitoring;
  9. 7-lead ECG waveforms display in phase;
  10. Capture dynamic waveforms;
  11. Built-in rechargeable lithium battery, and battery volume checking,
  12. AC power checking
  13. Efficient resistance to interference of defibrillator and HF knife;
  14. SINNOR F-6 SpO2 technology, VS NELLCOR accuracy;
  15. Networking capacity and TCP/IP networking platform enable abundant future upgrade
  16. Time delay switch-off function keep the monitor data restart monitor;
  17. Complete and flexible mounting solution for transportation and in-patient monitoring

Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.
Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,



Performance Specifications
Display: 12.1"color TFT
Rolling and refreshing waveform display
Resolution: 800×600
Multi display selectable including:
Large-font display
Trend coexist display
OxyCRG dynamic view display.
Bed-to-bed view display
Trace:9 waveforms(7 ECG, 1 SPO2 and 1 RESP)
Sweep speed:12.5mm/s,25mm/s,50mm/s
Indicator:  Power/battery indicator light
QRS beep and alarm sound
Battery: Rechargeable lead acid cell, 12v/4AH
Max.24 hour for charging, 4 hours for continue working
Trend: Parameter graphic and tabular trends:
5s/piece,8 hours;
1min/piece,168 hours(24hour×7days)
5min/piece,1000 hours.
Storage:     
NIBP: 1000 groups
Alarm: 200 groups
Full disclosure waveforms: 3600S
SD card external storage
Alarm: User-adjustable High, Medium and Low limits 3-level
 Audible and visual alarm
Networking: Connected to central monitoring system
TCP/IP netting platform
Recorder:  Build-in, thermal array
Plethysmogram caveform:2 channels
Record mode: manual, on alarm, time-defined 
Recording width: 50mm
Printing speed: 50mm/s
Recording type:    Frozen waveform record
NIBP recall record
Trend table record
Alarm record
Fixed -time record


Standard parameter:

ECG:

Lead mode: 5 -lead(R,L,F,N,C)
Lead selection : I,II,III,avR,avL,avF,V
Waveform:3 and 7 channel selectable
Gain selection: 0.5mm/mv,1mm/mv,2mm/mv
Sweep speed: 12.5mm/s;25mm/s;50mm/s
Heart rate range:    Adult: 15~300bpm;
Neonate/pediatric:15~350bpm
Accuracy: +1bpm or +1%,whichecer is greater
Resolution: 1bpm
Filter: surgery mode:1~20Hz
monitor model:0.5~40Hz
Diagnostic mode:0.05~130Hz
Scaling signal: 1mv,+3%
Protection:withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range: 15~350bpm
S-T segment detecton: 
Measurement range:  2.0mV~+2.0mV                        
 Alarm Range:        -2.0mV~ +2.0mV
Accuracy:           -0.8mV ~+0.8Mv
Error:              +0.02Mv
Arrhythmia analysis: YES


SPO2
Measurement range:  0~100%
Resolution:  1%
Accuracy:  +2%(70-100%);0-69% unspecified
Alarm range : 0~100%
Pluse Rate:              
range: 20~300bpm
Resolution:  1bpm
Error: +1bpm or +2%,whichever is greater


NIBP
Method:                  Digital Automatic oscillometric
Operation mode :           Manual/Automatic/continuous
Auto measurement time:     Adjustable(1~480min)
Measurement Unit:         mmHg/Kpa selectable
Measurement types:        Systolic, Diastolic, Mean  
Measurement tange:
Range of Systolic pressure:    Adult: 40~270mmHg
Pediatric: 40~220mmHg
Neonate: 40~135mmHg
Range of mean pressure:     Adult: 20~235mmHg
Pediatric: 20~165mmHg
Neonate: 20~110mmHg
Range of diastolic pressure:   Adult: 10~215mmHg
Pediatric: 10~150mmHg
Neonate :10~100mmHg
Over-pressure protection:    Double safety protection
Resolution:                1 mmHg
Alarm:                   Systolic.Diastolic,Mean


RESPIRATION
Method:                    Thoracic impedance
Measurement range:          Adult:7~120rpm;
Neonate/Pediatric:7~150rpm
Apnea alarm:                YES,10~40s
Resolution:                  1rpm
Accuracy:                   +2rpm


TEMPERATURE
Compatible probe:            YSI or CYF
Measurement range:          5~50ºC
Resolution :                  0.1ºC
Accuracy:                   +0.1ºC
Refreshing time:              about 1
Average measuring time:       <10s


FHR
Transducer:   Multi-crystal, Pulsed Doppler
Measurement range:  50~210 BPM
Working frequency:   1 MHz
Strength:   <5mW/cm2
Signal processing:  
special DSP system and modern recognization.
Resolution:   1BPM
Accuracy:   ±1BPM 
Alarm Range:  High: 160,170,180,190 BPM, 
Low: 100,110,120 BPM


FM
Manual button marking,
automatic FM identifying function


TOCO Measuring
Transducer:  External pressure transducer
Measurement range:  0~100 units
Resolution:  1rpm
Accuracy:  ±2 rpm


IBP
Channel: 2 channels
Range: -50-300mmHg
Resolution: 1mmHg
Accuracy: ±4mmHg(±4%)
Unit: mmHg, Kpa
Converter Sensitivity: 5mV/V/mmHg
Transducer sites: ART/PA/CVP/LAP/RAP/ICP


EtCO2( Sidertream CO2)
Measurement range:  0~99mmHg
Accuracy:  +2mmHg (0~40mmHg)
Sampling Range:  100ml/min
Sampling rate accuracy:  15%
Respiration rate:  0~120rmp
Respiration accuracy:  +2rmp (0~70rmp)
+5rmp (>70rmp)
Respiration time: <240msec (10% to 90%)
Delay time: <2s


EtCO2 (mainstreaam CO2)
Method:   Infrared Spectrum
Range:   0.0-10% (0~76%)
Resolution:   1mmHg (0.1%)
Accuracy:   <5%(±4.0 mmHg)
Or<10%(of Readings)


Recorder:     
Build-in, thermal array
Plethysmogram caveform:2 channels
Record mode: manual, on alarm, time-defined 
Recording width: 50mm
Printing speed: 50mm/s
Recording type:  Frozen waveform record
NIBP recall record
Trend table record
Alarm record
Fixed -time record


Miscellaneous
 
Satety:             
Safety level: Class I, type CF

Dimendion and Weight
Dimendion: 28*42*48cm        
G.Weight: <6.5KS

Operation Environment
Temperature:  Working 0~+40ºC
Transportation and storage -20~+60ºC
Humidity: working≤85%
Transportation and storage≤93%
Power:  AC 100-240,50/60Hz
Patient range:   Neonate,pediatric,and adult patients


Accessories supplies
(1) 5 lead ECG cable 
(2) 1 spo2 probes 
(3) 1 NIBP prbe  
(4) 1 temp probe
(5)1 ground connecting liner  
(6) Chest electrode (10pcs/set)
Product Tag:
Related categories:
Scroll to Top